www.whisperkool.com | Page 3
SC Series
Compressor is On
Unit is in Anti-Frost Mode
Fans are On
Alarm is present
Temperature Measurement
Controller Layout
Refer to page 30 for complete listing of buttons and symbols.
Unit Specications
2000i 3000i 4000i 6000i 8000i
Cellar Size (cu. ft.)
300 650 1000 1500 2000
Dimensions
14.25"W x 15.75"H x 17.5"D 14.25"W x 22.56"H x 21.64"D
Weight (lb.)
65 67 67 104 104
Amps (running)
2.7 4.9 4.9 10.3 10.3
dBA
60 60 60 65 65
Installation
Through-the-Wall, Partially Ducted
Thermostat
Digital control display
Temp. Delta
30°F temperature dierential
(maintains proper cellar temperature when exhaust environment does not exceed 85°F)
Outside Venting
! Not Recommended ! — Can only be done if the outside temperature does not exceed 85°F, the
optional external grille cover is required
Duct Options
Exhaust air can be ducted using the optional ducting kit
Warranty
2-year parts and labor / 5-year compressor
Menu Navigation
and Value Increase
* Press and hold
to manually enter
Anti-Frost mode.
Power On/O
(hold for approx. 3 seconds)
and Escape
Menu Navigation
and Value Decrease
Probe Values and
Alarm Folder
* Press and hold
to enter the
parameter menu.

Related product manuals