14 Wilo SE 07/2019
en
Preparation The current type and voltage must agree with the
specifications on the rating plate (4).
Maximum back-up fuse: 10 A, slow-blow.
Only operate the pump with sinusoidal AC voltage.
Note switching frequency:
- On/off switching operations via mains voltage
100/24 h.
- 20/h for a switching frequency of 1 min.
between switching on/off via mains voltage.
The electrical connection must be made via a fixed
connecting cable equipped with a connector device or
an all-pole switch with a contact opening width of at
least 3 mm (VDE 0700/Part 1).
Use a connecting cable with a sufficient outer diame-
ter (e.g. H05VV-F3G1.5) to protect against leaking
water and to ensure strain relief at the threaded cable
connection.
Use a heat-resistant connecting cable where fluid
temperatures exceed 90 °C.
Ensure that the connecting cable does not make con-
tact with either the pipes or the pump.
CAUTION!
Pulsed mains voltage can lead to damage to electronic
components.
Never operate the pump with phase angle control.
When switching the pump on or off using an external
control unit, deactivate any voltage pulsing
(e.g. phase angle control).
For applications where it is not clear whether the
pump is operated with pulsed voltage, get the
control/system manufacturer to confirm that the
pump is operated with sinusoidal AC voltage.
Switching the pump on/off via triacs/solid-state
relays must be examined on a case-by-case basis.