English MAINTENANCEANDREPAIR
Any other work and/or alterations to the
construction must only be carried out by Wilo
customer service.
• Whencarryingoutworkinbasinsand/ortanks,
the respective local protection measures must be
observed in all cases. A second person must be
present for safety reasons.
• Onlyliftingequipmentthatisinatechnically
perfect condition and load-carrying equipment
thathasbeenofciallyapprovedmaybeusedfor
lowering and raising the pump. Make sure that the
pump does not jam during lifting and lowering.
Ifthepumpdoesjam,noliftingforcesgreater
than 1.2 times the pump weight must be applied.
The maximum permissible bearing capacity must
never be exceeded!
Make sure that the lifting gear, ropes and the
lifting equipment's safety devices are in perfect
working order. Work may only commence if
the lifting equipment has been checked and
found to be in perfect working order. If it is not
inspected, fatal injuries may result.
• Electrical work on the pump and the system must
becarriedoutbyaqualiedelectrician.Defective
fuses must be replaced immediately. They must
neverberepaired.Onlyfusesforthespecied
electriccurrentandofthespeciedtypemaybe
used.
• Ifammablesolventsandcleaningagentsare
used,nakedamesandsmokingareprohibited.
• Pumpsthatcirculateuidsthatarehazardousto
healthorcomeintocontactwithsuchuidsmust
bedecontaminated.Inaddition,makesurethat
nogasesthatarehazardoustohealthformorare
present.
If injuries are caused by uids or gases that
are hazardous to health, apply the rst-aid
measures specied on the notice at the working
premises and notify a doctor immediately.
• Make sure that the necessary tools and materials
areavailable.Orderandcleanlinessensuresafe
and smooth work on the pump. After working on
thepump,removeanyusedcleaningmaterials
and tools from the pump. Store all materials and
tools in their proper place.
• Operatingmaterialsshouldbecollectedinsuit-
able containers and disposed of properly. Always
wear appropriate protective clothing when per-
forming maintenance and repair work. This must
also be disposed of properly.
8.1. Operating materials
8.1.1. Overview of white oil
Thesealingchamberislledwithwhiteoilthatis
potentially biodegradable.
Whenchangingtheoil,werecommendthefol-
lowingoiltypes:
• AralAutinPL*
• ShellONDINA919
• EssoMARCOL52*or82*
• BPWHITEMOREWOM14*
• TexacoPharmaceutical30*or40*
Alloiltypesmarkedwith“*”areapprovedforuse
withfoodsinaccordancewith“USDA-H1”.
Filling quantities
• TMT32M113/7.5Ci:900ml
8.1.2. Overview of grease
The following lubricating grease can be used in
accordancewithDIN51818/NLGlClass3:
• Esso Unirex N3
8.2. Maintenance intervals
Toensurereliableoperation,variousmaintenance
tasks must be carried out regularly.
Themaintenanceintervalsmustbespecied
according to the load on the pump. Regardless of
thespeciedmaintenanceintervals,thepumpor
installation must be checked if strong vibrations
occur during operation.
When used in sewage lifting units inside
buildings or on areas of land, the maintenance
intervals and work shown in DINEN12056‐4
must be adhered to.
8.2.1. Intervals for normal operating conditions
2 years
• Visual inspection of the power supply cable
• Visual inspection of accessories
• Visual inspection of the coating and housing for
wear
• Functionalinspectionofallsafetyandmonitoring
devices
• Inspection of the switchgear/relays used
• Oilchange
15000 operating hours or after 10 years at the
latest
• General overhaul
8.2.2. Intervals for harsh operating conditions
Underharshoperatingconditions,thespecied
maintenance intervals must be shortened accord-
ingly.Inthiscase,contactWilocustomerservice.
Ifusingthepumpunderharshconditions,wealso
recommend signing a maintenance contract.
Harshoperatingconditionsinclude:
• Alargeproportionofbrousmaterialorsandin
theuid
• Turbulentinlet(e.g.duetoairentry,cavitation)
• Stronglycorrosiveuids
• Stronglygassinguids
• Unfavourable duty points
• Operatingstatessubjecttowaterhammers
8.2.3. Recommended maintenance measures to en-
sure smooth operation
We recommend regular inspections of the current
consumption and the operating voltage in all 3
phases.Innormaloperation,thesevaluesremain
constant.Slightuctuationsdependonthechar-
acteristicsoftheuid.Thecurrentconsumption