38 WILOSE04/2014V05DINA4
English TROUBLESHOOTINGANDPOSSIBLESOLUTIONS
Always secure the pump against an accidental
restart by disconnecting it from the mains. Take
appropriate safety precautions.
Always have a second person on hand to ensure
the pump is switched off in an emergency.
Secure moving parts to prevent injury.
Unsanctioned changes to the pump are made at
the operator's own risk and release the manufac-
turer from any warranty obligations.
Fault: The unit will not start
1. Electricitysupplyinterrupted,shortcircuitor
earth fault in the cable or motor windings
Have the motor and wires checked by a special-
ist and replaced if necessary
2. Fuses,themotorprotectionswitchand/ormoni-
toring devices are triggered
Have a specialist inspect the connections and
correct them as necessary.
Have the motor protection switches and fuses
installed or adjusted according to the technical
specications,andresetmonitoringequip-
ment.
Checkthattheimpellerrunsfreely.Ifnecessary
clean it and ensure it runs freely again
Fault: The unit starts, but the motor protection
switch triggers shortly after commissioning
1. The thermal trigger on the motor protection
switch is incorrectly set
Have a specialist compare the setting of the
triggerwiththetechnicalspecicationsand
correct it as necessary
2. Increased power consumption due to major volt-
age drop
Have an electrician check the voltage on each
phase and rewire if necessary
3. Two-phase operation
Have a specialist inspect the connection and
correct it as necessary
4. Excessive voltage differences on the three phases
Have a specialist inspect the connection and
the switching system and correct as necessary
5. Incorrect direction of rotation
Swap the 2 phases of the mains supply
6. Impellerslowedbyaccumulation,cloggingand/or
solidmatter,increasedcurrentconsumption
Switchoffthepump,secureitagainstbeing
switched back on again and free the impeller or
clear the suction port
7. Theuidistoodense
Contactthemanufacturer
Fault: Unit is running but not pumping
1. Nouidavailable
Openinletfortankorslidevalve
2. Intake blocked
Cleanthesupplyline,slidevalve,suctionpiece,
suction port or suction strainer
3. Impeller blocked or slowed
Switchoffpump,secureitagainstbeing
switched back on again and free the impeller
4. Faultyhose/piping
Replace defective parts
5. Intermittent operation
Checkswitchingsystem
Fault: The unit runs, but not within the specied
operating parameters
1. Intake blocked
Cleanthesupplyline,slidevalve,suctionpiece,
suction port or suction strainer
2. Slide valve in the pressure pipe shut
Fullyopentheslidevalve
3. Impeller blocked or slowed
Switchoffpump,secureitagainstbeing
switched back on again and free the impeller
4. Incorrect direction of rotation
Replace two phases on the mains supply
5. Air in the system
Checkthepipelines,pressureshroudand/or
hydraulics,andventifnecessary
6. Pump pumping against excessive pressure
Checktheslidevalveinthepressurepipeand
openitcompletelyifnecessary,useadifferent
impeller,consulttheplant
7. Signs of wear
Replace worn parts
8. Faultyhose/piping
Replace defective parts
9. Inadmissiblelevelsofgasintheuid
Contactthemanufacturer
10. Two-phase operation
Have a specialist inspect the connection and
correct it as necessary
11. Excessive decrease in the water table during
operation
Checkthesupplyandcapacityofthesystem,
and inspect the level control settings and
functionality
Fault: The unit does not run smoothly and is
noisy
1. Pump is operating in an inadmissible range
Checktheoperationaldataofthepumpand
correct if necessary and/or adjust the operating
conditions
2. Suctionport,suctionstrainerand/orimpeller
clogged
Cleanthesuctionport,suctionstrainerand/or
impeller
3. Impeller stiff
Switchoffpump,secureitagainstbeing
switched back on again and free the impeller
4. Inadmissiblelevelsofgasintheuid
Contactthemanufacturer
5. Two-phase operation
Have a specialist inspect the connection and
correct it as necessary
6. Incorrect direction of rotation
Replace two phases on the mains supply
7. Signs of wear
Replace worn parts
8. Defective motor bearing
Contactthemanufacturer
9. Pump is installed under tension
Checkinstallation,useexpansionjointsif
necessary