Maintenance27221/A2
RT-flex58T-E
Winterthur Gas & Diesel Ltd.
8/ 12
6. Adjusting the opening pressure
Install the injection valve in the test bench as described in section 2.
The opening pressure of the injection valve can be set by adjusting spring
tensioner 7.
For readjusting the opening pressure, compression spring 12 must first be
completely released by means of spring tensioner 7.
Then operate the valve test bench and tighten the spring tensioner simulta-
neously until the required opening pressure is reached.
Check the injection valve as described in section 2.
After adjusting the opening pressure, tighten collar nut 6.
Remark: An opening pressure of 460 bar corresponds with the reference
dimension ’x
1
’ = 33.30 mm .