Tools: Key to Illustrations:
2 Spacers GF 94555A 1 Fuel pump 8 Toothed rack
2 Actuator 9 Set screw
3 Shaft 10 Self-locking nut
4 Lever 11 Mark
5 Clamping sleeve
6 Screw
7 Connecting element
1. General
⇒ Make sure that the connecting element (1, Fig. A) is lubricated with Molykote
paste G.
⇒ Make sure that the connecting element (1) can move freely.
A
1
2
WCH03870
DATA FOR
RT−flex50−B
Regulating Linkage
Adjusting with Woodward ProAct II − Digital Actuator
2018−02