SECTION 7 –
PLUMBING
7-4
• Remove the bowl and pull the strainer screen
out of the bowl to tap out any particles and
rinse clean.
• Insert the strainer screen back into the bowl,
then screw the bowl back onto the strainer
assembly.
NOTE: You must also empty the strainer when
winterizing your coach to avoid water
freezing and cracking the filter bowl.
Water Pump Switch
The Water Pump switch is located near the
monitor panel (some models may have an
additional switch in the water service center or
within the bathroom area for your convenience).
While the switch is “ON”, the pump will
automatically supply water as it is needed.
We recommend that you turn the Water Pump
switch off whenever you will be away from the
vehicle or not using the water system. In time, a
slow leak in a faucet could drain the water tank,
fill the holding tank, and discharge the house
batteries.
Initial Waterline Priming
1. Ensure that all water drain valves are closed,
including water heater valve.
2. Turn Water Pump switch to “OFF” position.
3. Fill water tank.
4. Open all faucets, hot and cold.
5. Turn ON the Water Pump switch.
6. Close each faucet as it begins to deliver a
steady stream of water (close cold water first.)
Leave hot water faucets on until they also
deliver a steady stream of water. This will
ensure that the water heater is filled with
water.
7. Check to ensure the Water Pump stops soon
after all faucets have been closed.
8. The Water Pump is now ready for automatic
operation. The pump will start when a faucet
is opened and stop when the faucet is closed.
DISINFECTING YOUR FRESH
WATER SYSTEM
(As required by NFPA
®
1192 Standard on
Recreational Vehicles)
To ensure complete disinfection of the potable
water system, it is recommended that the
following procedure be followed on a new
system, one that has not been used for a period of
time, or one that could have become
contaminated.
This procedure is also recommended before
long periods of storage, such as over winter.
Disinfecting with Gravity Fill
1. Prepare a chlorine solution using 1 gallon of
water and 1/4 cup of household chlorine
bleach (sodium hypochlorite solution). With
tank empty, pour chlorine solution into the
tank. Use 1 gallon solution for each 15 gallons
of tank capacity. This procedure will result in
a residual chlorine concentration of 50 ppm in
the water system.
If a 100 ppm concentration is desired as
discussed in Step 4, use 1/2 cup of household
bleach with 1 gallon of water to prepare the
chlorine solution. One gallon of this solution
should be used for each 15 gallons of tank
capacity.
Water Pump
(Located beneath bed)
-Typical installation shown