User Manual WMF1200 S
Accessories and spare parts
Installation clearances For operating, service and safety reasons the machine
should be installed with aclearance of not less than
50mm at the back and sides from the building
or non-WMFcomponents. Aminimum working
space of 800mm in front of the coffee machine is
recommended. Aclear height of 1,100mm from the top
of the supporting surface should be ensured. The height
of the installation surface above the floor is at least
850mm. If the coffee machine connections are to be
run downwards through the counter, please make space
for the lines, which can reduce the usable space below
the machine.
Installation dimensions
of the water filter
See the User Manual for the water filter.
These specifications for the electrical connection and the standards quoted
apply for connecting the coffee machine in EU countries. It may be necessary
to also observe additional country-specific regulations. Outside the EU
countries acceptance of the standards quoted is to be checked by the legal
entity or natural person who wishes to use the coffee machine.
The local power supply must be constructed according to the currently valid
IEC 364 (DIN VDE 0100). To improve safety, the device should be fitted with an
FI 30mA earth leakage current circuit breaker complying with EN 61008. (Type
Bresidual current circuit breakers provide reliable tripping even if the fault current
is smooth. This ensures ahigh level of safety.) Near the device or about 30cm
below the counter top there should be ashockproof socket as asingle-phase
connection installed locally on the rear or side wall of the counter substructure
or acountry-specific single-phase socket. If the mains cable for this device
is damaged then it must be replaced by our service personnel or asimilarly
qualified person, in order to prevent hazards. The mains cable must not come into
contact with hot surfaces. The mains switch and plug top are part of the on-site
installation. The coffee machine may not be fitted with afixed permanent mains
connection if installed on atransporting trolley (a mobile station).
In order to avoid possible faults from arising on our shielded data lines due to
potential equalisation currents between the devices, an additional potential
equalisation unit should be planned for devices connected to the vending system.
(See EN 60309)