15
User Manual WMF9000 F VB
Safety
Installation location
• The machine must be set up so as to allow good visual access.
• The device must be placed and leveled on ahorizontal, sturdy,
water-resistant, and heatproof base.
• The device must not be cleaned using awater jet. The device
must be installed where it is protected against water spray.
• The device must not be located on asurface that is sprayed or
cleaned with awater hose, steam jets, steam cleaner, or similar
devices.
Water supply
On site:
• ½" (TW12) with main shutoff valve and dirt filter (250µm)
• Min. 0.36MPa (3.6bar) supply pressure at 6l/min
(1
Note
To ensure proper function of the
setting routine for the pressure
reducer, the minimum required
pre-pressure across the machine
connection is 2.4bar (at 6l/min).
Atlower pressure, the pressure
difference will not be sufficient to
adjust the pressure reducer to the
setvalue.
(1
This takes the normal pressure losses via water supply set and water
filter into account. As aresult, the flow pressure of 0.2MPa (2bar)
at6l/min required by the machine for maximum hourly output
willbeensured.
NOTE