83
User Manual WMF9000 F VB
Appendix: Technical data
These specifications for the electrical connection and the standards quoted
apply for connecting the coffee machine in EU countries. It may be necessary
to also observe additional country-specific regulations. Outside the EU
countries acceptance of the standards quoted is to be checked by the legal
entity or natural person who wishes to use the coffee machine.
The customer's on-site electrical system must be designed to meet country-
specific regulations per IEC60364and must match the information on the rating
plate.
An isolated ground socket or acountry-specific single-phase socket for
single-phase connection, or a5-pole CEE/CEKON socket per DINEN50310
VDE0800–2-310or acountry-specific multi-pole socket for athree-phase
connection, must be available near the machine. The sockets are part of the
customer‘s on-site installation. The power cord must not come into contact with
hot surfaces. If the power cord for this device is damaged then it must be replaced
by our service personnel or asimilarly qualified person, in order to prevent hazards.
In order to avoid possible faults from arising in our shielded data lines due to
potential equalisation currents between the devices, an additional potential
equalisation unit should be planned for devices connected to the vending system
(see DINEN50310 VDE0800–2-310).
If the machine is intended to be installed in alarge kitchen, it is recommended
that it be equipped with aground potential bonding conductor. The potential
equalisation terminal is installed by WMFService if needed.