EasyManua.ls Logo

Wolf CGB-100 - Vertical Concentric Balanced Flue Examples

Wolf CGB-100
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
513062555_201804
Balancedueroute,verticalandconcentric(examples)
1 Gascondensingboiler
2 Gascondensingboiler
connectionsDN110/160
3 Inspectionpiece
3a Inspectionpiece,87°tee
4 PipeclipDN160
5 BalancedueDN110/160
500 mm
1000 mm
2000 mm
6 MountingbracketDN160
for roof outlet
7 Universaltilefor
pitchedroof25-45°
7a "Klöber"adapter20-50°
8 Flatroofcollar
9 Balancedueroutingvertical
(roofoutlet)
foratorpitchedroof
L=2000mm
10 Bend 45° DN 110/160
11 Bend 87° DN 110/160
12 87°bendforductinstallation
DN 110/160
13 ExternalwallsupportbendF87°
withsmoothendsonbothsideof
theairpipeDN110/160
14 Airinlet,externalwallF
DN 110/160
15 PPwalloutlet,externalwallF
16 Wallplate160
17 Balancedueroutinghorizontal
incl. cowl
18 Connectiontouegaschimney
B33,Length 250 mm with air
apertures
19 Supportbend87°, DN 110
forconnectiontoaueinaduct
20 Supportrail
Notes: Lubricate the pipe ends and gaskets for easi-
er installation.
Check the required inspection piece
(3), (3a) (Part No.: 2651329) with your local
uegasinspectorpriortoinstallation.
TypeC33x:Gascondensingboilerwithcombustionairanduegas
routed vertically via the roof.
Ventilation air aperture for room sealed operation
accordingtoTRGI150cm²or2x75cm².
7
7a
6
8
56
11
3
3
3
5
4
4
4
5
5
5
5
10
10
2
1
2
1
2
1
3a
6
9
6
9
6
9
28.Technicalinformation