Induction Cooktop
Technical Data
6-2
THIS APPLIANCE MUST BE PROPERLY GROUNDED AT ALL TIMES WHEN ELECTRICAL POWER IS APPLIED.
DO NOT GROUND THE APPLIANCE WITH THE NEUTRAL (WHITE) HOUSE SUPPLY WIRE. A SEPARATE
GROUND WIRE MUST BE UTILIZED.
IF ALUMINUM HOUSE SUPPLY WIRING IS UTILIZED, SPLICE THE APPLIANCE COPPER WIRE TO THE
ALUMINUM HOUSE WIRING USING SPECIAL CONNECTORS DESIGNED AND CERTIFIED FOR JOINING
COPPER AND ALUMINUM. FOLLOW THE CONNECTOR MANUFACTURES RECOMMENDED PROCEDURE
CAREFULLY. IMPROPER CONNECTION CAN RESULT IN A FIRE HAZARD.
To eliminate the risk of burns or fi re by reaching over heated surface units, cabinet storage
space located above the surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood that protects horizontally a
minimum of 5” (127 mm) beyond the bottom of the cabinets.
1200 W Split 1800 W Quad 4000 W Quad
Power level # of LEDs Watts Watts Watts
0Off 0 0 0
1 1 33.36 50 83
2 2 66.72 100 167
3 4 133.32 250 333
4 6 200.04 375 500
5 8 266.64 500 667
6 10 316.68 600 792
7 12 399.96 800 1000
8 14 600 1000 1500
9 15 900 1500 2250
10 16 1200 1800 3000
HI POWER HI POWER
LED
N/A 3000 4000
Element Power Consumption
Supply Power Requirements
Nominal voltage:
Model CT15I ...................... 240 VAC / 50/60 Hz / 20 amp service
208 VAC / 60 Hz / 20 amp service
Model CT30I & CT30IU ..... 240 VAC / 50/60 Hz / 40 amp service
208 VAC / 60 Hz / 40 amp service
Model CT36I & CT36IU .... 240 VAC / 50/60 Hz / 50 amp service
208 VAC / 60 Hz / 50 amp service
Supply voltage range: 177 – 265 VAC, 50 or 60 Hz.
NOTE: Showroom mode will work on a 120V or 240V power source.