31
Cooling
MINIMUN CABLE SIZE
CONDENSING UNIT TOTAL UNIT MOTOR RATED MOTOR RATED UP TO 25m UP TO 50m
MODEL FLC (A) LRA (A) FUSE SIZE (A) MCB SIZE (A) mm
2
mm
2
BMOP130-1 13.5 45 16 16
1.5mm²
2.5mm²
BMOP150-1 15.4 45 16 16 1.5mm² 2.5mm²
BMOP190-1 16.8 54 20 20 1.5mm² 2.5mm²
BMOP210-1 20.4 60 25 25 1.5mm² 4.0mm²
BMOP250-1 23.6 70 25 25 2.5mm² 4.0mm²
BMOP250-3 9.1 28 16 16 1.5mm² 1.5mm²
BMOP320-1 28.7 83 32 32 2.5mm² 4.0mm²
BMOP320-3 11.6 30 16 16 1.5mm² 1.5mm²
BMOP350-3 11.5 30 16 16 1.5mm² 1.5mm²
BMOP360-3 15.9 43 20 20 2.5mm² 2.5mm²
BMIEP running amps
EVAPORATOR
UNIT
MODEL
FAN MOTOR HEATER
MOTOR
RATED FUSE
SIZE A
MOTOR
RATED
MCB SIZE A
NUMBER DIAMETER
TYPE
POWER 230V 1ph
MAX
FLC (A)
POWER 230V 1ph
FLC (A)
FLC (A) mm W W
BMIEP - 448-37 1 300 EC 84 0.67 1100 4.8 16 16
BMIEP - 448-48 1 300 EC 88 0.68 1100 4.8 16 16
BMIEP - 448-69 2 300 EC 168 1.34 2200 9.6 20 20
BMIEP - 448-89 2 300 EC 176 1.36 2200 9.6 20 20
BMIEP - 448-133 3 300 EC 264 2.04 2200 9.6 20 20
24. Electrical