14.3 BC10 Display settings
14.4 BC10 Display codes
Display settings
Display
setting
Meaning of display setting Unit Range
Factory
adjusted
setting
[l/9/9| Configured target load (50 kW). % [l/3/0| [l/9/9| / [l/-/-| 100 % [l/-/-|
[l/9/9| Configured target load (65 kW). % [l/2/0| [l/9/9| / [l/-/-| 100 % [l/-/-|
[l/9/9| Configured target load (80 kW). % [l/2/5| [l/9/9| / [l/-/-| 100 % [l/-/-|
[l/9/9| Configured target load (100 kW). % [l/2/0| [l/9/9| / [l/-/-| 100 % [l/-/-|
[f/\.5| Configured target value of the pump run-over time.
Note: Do not set a pump run-over time of less than [f/\/5|
(= 5 minutes).
min. [f/0/0| [f/6/0| / [f/1/d| 24 h [f///5|
[c/\/1| DHW supply operating condition setting.
Please note: If the setting [c/\/0| is displayed, the frost protection of
the DHW supply has also been switched off.
Not appli-
cable.
[c/\/0| Off / On [c/\/1|
Table 23 Display settings
Display codes
Display code
LED on
UBA 3
Other effectsz
Main
display
code
z
Sub
display
code
z Key to display code
Reset
requi-
red?
[\/-/\|
Operating phase:
Communication test while starting up. This display code
flashes 5 times within 5 seconds while starting up to
indicate that the communication between the UBA 3 and
the BC10 basic controller is being tested. If a new UBA 3
or a new KIM was fitted, this code will flash for max.
10 seconds.
Off or
flashing
at 8 Hz
[\/-/\|
Fault:
If this code continues to flash on the display, there is a
fault in the communication between the UBA 3 and the
BC10 basic controller.
Off or
flashing
at 8 Hz
e
[-/a/\]
1)
e
[2/0/8|
2)
Operating phase:
The boiler is in flue gas test or service mode.
Off or
flashing
at 8 Hz
No heating operation and no
DHW.
e
[-/h/\|
e
[2/0/0|
2)
Operating phase:
The boiler is in heating mode.
Off
e
[-/h/}
3)
e
[2/0/0|
2)
Operating phase:
The boiler is in manual operation mode.
Off The room temperature is too
high.
e
[=/h/\|
e
[2/0/1|
2)
Operating phase:
The boiler is in DHW mode.
Off
e
[=/h/\|
e
[2/0/1|
2)
Operating phase:
Pump run-over time via the external hot water cylinder
130 seconds at the minimum speed. The “Burner” LED
(On/Off) is off.
Off
e
[0/a/\|
e
[2/0/2|
2)
Operating phase:
The switch optimization program is activated. This
program is activated if there has been any demand more
frequently than once every 10 minutes. This means that
the boiler cannot be restarted until at least 10 minutes
have elapsed since initial burner start-up.
Off The room temperature is not
possibly reached.
e
[0/a/\|
e
[3/0/5|
2)
Operating phase:
The boiler cannot start up temporarily after a DHW
request has ended.
Off
Table 24 Display codes