10.3 Heating/hot water output settings ZWBR 7-28 N.G.
10.4 Heating/hot water output settings ZWBR 11-28 L.P.G
Natural gas G20
Display
code
Heat output,
kW
Heat input,
kW
Gas vol. flow rate (l/min at t
V
/t
R
= 80/60 °C)
30 8.5 8.6 15.0
40 11.3 11.4 20.0
50 14.1 14.3 24.9
60 16.9 17.1 29.9
70 19.8 20.0 34.9
80 22.6 22.8 39.9
90 25.4 25.7 44.9
100 28.2 28.5 49.9
Table 20
Propane
Display
code
Heat output,
kW
Heat input,
kW
40 11.3 11.4
50 14.1 14.3
60 16.9 17.1
70 19.8 20.0
80 22.6 22.8
90 25.4 25.7
100 28.2 28.5
Table 21