After the centrifugal force has been set, loosened screws
must be fastened again and the protective covers
reassembled (for tightening torques see below). Otherwise
there is a risk of accident! In order to guarantee the
tightness of the motor, it is important to ensure that the
seals are intact when dismantling and assembling the
protective covers. Damaged seals must be replaced.
Operating the vibrator motors without unbalance discs
is not permitted.
Tightening torques for the screws in the protective covers
Tightening torques of the screws to fix the unbalance discs
M5
M6
M8
M10
M12
4,0 Nm
6,0 Nm
10,0 Nm
20,0 Nm
30,0 Nm
M8
M10
M12
M16
M20
M24
30,0 Nm
40,0 Nm
50,0 Nm
200,0 Nm
340,0 Nm