84
DC, 3000 min
-1
Motor
Bearing
Initial Fill
Relubrication Intervall
Relubrication Amount
Bearing Life
g
g
g
h
50 Hz
60 Hz
50 Hz
60 Hz
HV 2 GL
6002 ZZ C4
-
-
-
-
-
5800
HV 2 GL Verst.
6002 ZZ C4
-
-
-
-
-
1000
HF, 6000 min
-1
200Hz, 3000 min
-1
200Hz
Only Mobil UNIREX N3 grease may be used for relubrication.
If the bearings show signs of wear, the devices should be taken out of operation
immediately and both special bearings should be replaced.
We recommend sending the devices (also in the event of other damage) to the
manufacturer for repair.
Please note that we do not use commercially available bearings in our motors,
these are specially made for us.
Motor
Lager
Initial Fill
Relubrication Intervall
Relubrication Amount
Bearing Life
g
g
g
h
50 Hz
60 Hz
50 Hz
60 Hz
200 Hz
HF 2
6302 ZZ C4
-
-
-
-
-
1225
HF 6/4
6302 ZZ C4
-
-
-
-
-
1800
HF 6/4-6100
6303 ZZ C4
-
-
-
-
-
380
HF 6/8
6303 ZZ C4
-
-
-
-
-
3800
HF 8
6306 ZZ C3
-
-
-
-
-
385
HF 15
NJ2305E C4
8,0
-
-
-
-
1560