EasyManuals Logo

Xantrex 200 User Manual

Xantrex 200
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #61 background imageLoading...
Page #61 background image
Troubleshooting Reference
975-0057-01-01 5-3
AC appliance
will not
operate;
audible alarm
is sounding.
Battery has discharged
to 10.5 V.
Inverter has
overheated due to poor
ventilation or
excessively warm
environmental
conditions.
Turn the AC Outlet On/Off switch
off and recharge the XPower
Powerpack.
Turn the AC Outlet On/Off switch
off and allow the XPower
Powerpack to cool for 15 minutes or
more. Clear blocked fan opening or
remove objects covering the unit,
then restart the XPower Powerpack.
Move to a cooler environment.
Over-
temperature
shutdown
Inverter has
overheated due to poor
ventilation or
excessively warm
environmental
conditions.
Turn off the AC Outlet On/Off
switch, and let the XPower
Powerpack cool down.
Alarm sounds Internal battery is
nearly discharged.
(11.0 V).
If you ignore this
warning, the XPower
Powerpack
automatically switches
off when the battery
reaches 10.5 V.
Turn the AC outlet ON/OFF switch
OFF and recharge the XPower
Powerpack.
Run time is
less than
expected.
Internal battery is not
fully charged.
AC appliance power
consumption is higher
than expected.
Recharge using the AC Charger,
until green Charging Status light is
steady.
Check AC appliance power or
wattage rating (or current draw for
12 V DC appliances) and compare
with Table 3-1 on page 3–5 and
Table 3-2 on page 3–9.
Table 5-1
Troubleshooting reference
Problem Possible Cause Solution

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex 200 and is the answer not in the manual?

Xantrex 200 Specifications

General IconGeneral
BrandXantrex
Model200
CategoryPower Pack
LanguageEnglish

Related product manuals