Troubleshooting Reference
975-0057-01-01 5-5
Green
Charging
Status light is
still flashing
and hasn’t
changed to
steady after 50
hours of
charging.
The voltage at the AC
wall outlet is less than
120 V AC.
Internal battery is
permanently damaged.
Use AC wall outlet that supplies 120
V AC.
Replace the battery.
The
compressor
runs but won’t
inflate
(XPower
Powerpack
400 Plus only).
The valve connector
may not be securely
placed on the valve
stem.
The item being
inflated may have a
leak.
Check that the valve connector is
securely placed on the valve stem
before closing the thumb latch.
Check that the item being inflated
has no leaks.
Check the compressor hose for any
breaks or leaks at connections.
The
compressor
runs slowly
(XPower
Powerpack
400 Plus only).
The compressor may
have overheated from
excessive use.
Battery voltage is too
low.
Turn off the compressor and let it
cool down.
Check the condition of the internal
battery. The battery may need to be
recharged or replaced.
Table 5-1
Troubleshooting reference
Problem Possible Cause Solution