Specifications
A-2 975-0057-01-01
AC Power Section
Output power
Continuous output power
Five minute AC output power
AC output surge capacity
320 W
400 W
600 W
Output voltage 115 ± 10 V AC RMS
Output frequency 60 Hz ± 4 Hz
Output wave form modified sinewave
No load current draw <0.20 A DC
Input voltage range 10.5 to 15.0 V DC
Low battery alarm 11.0 V DC
Low battery shutdown 10.5 V DC
High battery voltage shutdown Yes, automatic reset
Over temperature shutdown Yes, automatic reset
Overload shutdown Yes, automatic reset
AC output short circuit protection Yes, automatic reset
Fuse (internal) 2 x 25 A or 1 x 50 A
Operating temperature range 32 – 104 ºF
(0 – 40 ºC)
Storage temperature range 32 – 86ºF
(0 – 30 ºC)
Internal Battery Charging Controller System
AC Charger bulk charging current 750 mA
Peak charging voltage (nominal) 14.2 V
Charge restart voltage (nominal) 12.9 V
Float charge after full charge is completed
(nominal)
1 mA
AC Charger input socket maximum current 2.5 A