Section 1. Features and Specifications
Additional Electrical Specifications
Release 1.2 15
Additional Electrical Specifications
Input Conditions
Voltage Mode Transient Response
(Time for the output voltage to
recover to ±50 mV band for 50%
load change in the range of 25% to
100% of the rated load.)
<500 µs
Time delay from power on until
output stable
1.5 s maximum
Rated AC Input Voltage 120 Vac standard; 230/240 Vac AC200 option
Maximum AC Input Power 625 VA
Operational AC Input Voltage Range Single Unit: 104
127 Vac at 6 Arms
Dual Unit: 104
127 Vac at 12 Arms
AC 200 Option Single Unit: 200
250 Vac at 3 Arms
Dual Unit: 200
250 Vac at 6 Arms
Maximum Input Current (per unit) at
nominal power line impedances
6 A maximum at 104 Vac
Input Frequency Range 47
63 Hz