Section 2. Installation
Rack Mounting
22 Operating Manual for HPD Series Power Supply
Rack Mounting
Use the power supply in benchtop or in rack-mounted applications.
The power is supply is designed to fill one quarter of a standard 19 in. (483 mm)
equipment rack.
Dual and quad configurations can be combined with 60 watt series models for
custom applications. Contact the manufacturer about the rack mount kit (Option
RM).
Location and Ventilation
Whether you place the power supply in a rack or on a bench, allow cooling air to
reach the ventilation inlets on the bottom and sides of the unit. Ensure that
rack-mounted supplies have 1 U (1.75 in./44.5 mm) above and below units. Any
ventilation space around the supply will further lower internal operating
temperatures.
See “Environmental Specifications” on page 16, for the operating altitude
specification and the operating ambient temperature range measured at the unit case.
WARNING
Ensure that any mounting screws do not protrude more than 1/8 in. (3.0 mm) into the
bottom of the unit.