17
2.0 INSTALLATION
©2000 Xantrex Technology Inc.
+ - + -
6 V 6 V
+ -
12 V INVERTER
(Total battery capacity = 100 Ah)
3597-F00-D21
+ - + -
6 V 6 V
+ -
24 V INVERTER
(Total battery capacity = 100 Ah)
3597-F00-D22
+ - +
6 V 6 V
-
+ - + -
12 V 12 V
+ -
24 V INVERTER
(Total battery capacity = 50 Ah)
3597-F00-D24
Figure 11
6 Volt Battery WiringSeries Configuration
Each batterys amp-
hour rating is 100 Ah
Each batterys amp-hour
rating is 50 Ah
Wiring (continued)
Wiring Batteries in Series
Wiring the batteries in a series configuration increases the voltage of the battery string. 6 volt
batteries can be combined to form 12 V, 24 V, or 48 V battery banks. In the same way, 12 volt
batteries connected in series form 24 V or 48 V battery banks. The total current capacity of the bank
does not increase and it retains the same amp-hour rating as a single battery.
Figure 12
12 Volt Battery WiringSeries Configuration
+ - + -
6 V 6 V
+ -
48 V INVERTER
(Total battery capacity = 100 Ah)
3597-F00-D23
+ - + -
6 V 6 V
+ - + -
6 V 6 V
+ - + -
6 V 6 V
+ - + -
12 V 12 V
+ -
48 V INVERTER
(Total battery capacity = 50 Ah)
3597-F00-D25
+ - + -
12 V 12 V