44 Truecharge2 Series Battery Charger Owner’s Guide
Accessing Charger Information
Low Battery Temp fault
(< -25°C)
Check the batteries. Do not charge a frozen battery.
Charging a frozen battery may present a risk of
explosion. Check that the battery type and
temperature settings match the actual battery.
Allow the battery (or batteries) to warm up to a
temperature that is above freezing before charging.
See “Specifications” on page 54.
High Battery voltage
fault
(>16.5V for 12-volt
chargers)
(>33V for 24-volt
chargers)
Discontinue charging or disconnect AC power source
from supplying power to the charger.
Disconnect voltage sensitive DC loads from DC
supply to prevent damage.
If the DC bus voltage is still measuring high after AC
power has been disconnected, call a qualified and
certified electrician.
High Charger Temp
fault
Allow the Truecharge2 Battery Charger to cool while
the AC is connected so the fan stays on.
Improve ventilation or install the charger in a cooler
location.
Loss of Remote
Connection warning
Reconnect the communication cable to the port. It
takes about 15 seconds to re-establish
communication.
Flashing LED Solid LED
Table 9
Interpreting Fault and Warning Indicators
Fault or Warning
Condition
Temp Fan AC Battery Fuse Charger Remote Fault
Solution
F
u
s
e
C
h
g
r
R
e
m
TC2 204060 Series BattChg Owners Guide.book Page 44 Friday, July 8, 2011 11:44 AM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex truecharge 2 series and is the answer not in the manual?

Xantrex truecharge 2 series Specifications

General IconGeneral
Input Voltage90-265 VAC
Input Frequency47-63 Hz
Number of Banks3
DimensionsVaries by model
WeightVaries by model
Output Voltage12 VDC or 24 VDC
Output Current20A, 40A, or 60A
Battery TypesFlooded, Gel, AGM
Charging Stages3-stage (Bulk, Absorption, Float)
Protection FeaturesOvervoltage, Overcurrent, Short Circuit, Reverse Polarity, Over Temperature
Operating Temperature-20°C to +50°C