Operation
3–4
Using A Generator As Source Power
The Truecharge+ can be run from a regular power source or from an
alternate power source such as a generator. Refer to Appendix A,
“Specifications” for AC input draw to determine the size of generator you
need.
Many generators provide output voltage that is modified sine wave
(MSW) rather than the true sine wave (TSW) that your utility provides.
Xantrex does not recommend the use of Truecharge+ with MSW
generators due to increased heating of the charger.
Indicator Light Activity On The Front Panel
Indicator light activity shows what is happening during the charging
process and is also helpful in troubleshooting. Refer to Chapter 4,
“Maintenance and Troubleshooting for more information about
interpreting indicator lights.
During the charging process, indicator lights are interpreted as follows:
Activity Charger status
Charging indicator light is
lit
The unit is charging in bulk or absorption
mode
Both Ready and Charging
indicator lights illuminate
The unit is performing the pre-equalization
absorption charge or is performing the
equalization charge.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex Truecharge 40+ Amp and is the answer not in the manual?

Xantrex Truecharge 40+ Amp Specifications

General IconGeneral
BrandXantrex
ModelTruecharge 40+ Amp
CategoryBattery Charger
LanguageEnglish

Related product manuals