EasyManuals Logo

Xantrex Truecharge 40+ Amp User Manual

Xantrex Truecharge 40+ Amp
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #48 background imageLoading...
Page #48 background image
Maintenance and Troubleshooting
4–4
Typical Problems
This section lists typical problems you may have with the Truecharge+,
suggests their causes, then offers possible solutions to the problems.
Symptom Indicator lights do not turn on, or remain on, when charger is
connected to an AC receptacle.
Symptom Indicator lights continue to blink when charger connected to
battery. Charging indicator light does not turn on continuously.
Possible Cause Solution
1. No power at AC
receptacle
2. Defective wiring
3. Open fuses in charger
1. Ensure that power is available at
receptacle
2. Replace wiring
3. Have charger serviced by
qualified person
Possible Cause Solution
1. Charger does not detect
battery for one of
following reasons:
poor connection
reverse polarity
connection
damaged wiring
open fuse in charger
2. Battery voltage is too low.
1. Check polarity and quality of
battery connection.
If cables are damaged or internal
fuse open, have the charger
serviced by a qualified person.
2. Check the battery.
Do not attempt to charge a 6 volt
battery. If battery is rated for 12
volts, leave it connected for 8
hours to see if it will recover. If
battery doesn't start charging
after 8 hours, it is permanently
damaged and will not accept a
charge.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex Truecharge 40+ Amp and is the answer not in the manual?

Xantrex Truecharge 40+ Amp Specifications

General IconGeneral
BrandXantrex
ModelTruecharge 40+ Amp
CategoryBattery Charger
LanguageEnglish