56 Truecharge2 Series Battery Charger Owner’s Guide
Specifications
Float voltage:
Flooded
GEL
AGM
Lead-calcium
12-volt units 24-volt units
25 °C (77 °F) 25 °C (77 °F)
13.5 ±0.1 27.0 ±0.2
13.8 ±0.1 27.6 ±0.2
13.4 ±0.1 26.8 ±0.2
13.5 ±0.1 27.0 ±0.2
Equalize mode current 50% rated output ±6%
Equalize mode—maximum
output voltage
12-volt units:
24-volt units:
16 ±0.1 Vdc
32 ±0.2 Vdc
Off-state current draw
(without remote installed) <35 mA dc
DC Output Specifications
Voltage regulation Uncompensated load voltage
regulation
< 0.1Vdc drop from 0 Amps to rated
current output at charger output
terminals (adds in series with
recommended 3% limit for user's
battery cable voltage drop).
Environmental Specifications
Operating range 0 – 60 °C (32 – 140 °F)
with up to 80% current derating
above 40 °C (104 °F) and
up to 50% current derating
above 50 °C (122 °F)
Storage –40 to 80 °C (–40 to 176 °F)
Humidity 5 – 95%, RH non-condensing
DC Output Specifications
TC2 204060 Series BattChg Owners Guide.book Page 56 Friday, July 8, 2011 11:44 AM