Suitable modelMP360-LMP760-T
3-7LG Master-K series
1. Software settings
Parameters
Recommended settings
Master-K80/120S
K80/120S (Cnet)
MP communication port
Communication port
PLC communication port
Terminal port
Multifunctional port
Communication type
RS232
Communication distance
15m
Data bit
8
Stop bit
1
Verification mode
None
Baud rate
38400
9600
Modbus number
1
2. Address
PLC address
Operational range
Data type
Description
M
0~9999F
Bit
Internal auxiliary coil
L
0~9999F
Bit
Connection relay coil
K
0~9999F
Bit
Hold relay coil
F
0~9999F
Bit
Read only data registers
T
0~9999
Bit
Timer coil
C
0~9999
Bit
Counter coil
D
0~9999
Bit
Data registers
P
0~9999F
Bit
Input / output coil
D
0~9999
Word/D Word
Data registers
TD
0~9999
Word/D Word
Timer current value
CD
0~9999
Word/D Word
Counter current value
S
0~9999
Word/D Word
Registers
K
0~9999
Word/D Word
Registers
M
0~9999
Word/D Word
Registers