EasyManua.ls Logo

Xinje MP Series

Xinje MP Series
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
64
(11) connect to the port of Socket B/B1 and B2PCD2.F520/F530
Suitable modelMP330MP330-SMP360-LMP760-T
3-16Fuji SPB series
1. Software settings
parameters
Recommended settings
MP communication port
Communication port
PLC communication port
Terminal port
Communication type
RS232
Communication distance
15m
Data bit
8
Stop bit
1
Verification
Odd
Baud rate
19200
Modbus number
1
2. Address
PLC address
Operational range
Data type
Description
X
0~15
Bit
External input coil
Y
0~15
Bit
External output coil
M
0~15
Bit
Internal auxiliary coil
L
0~15
Bit
Special auxiliary coil
T
0~511
Bit
Timer status
C
0~255
Bit
Counter coil
SM
0~15
Bit
Special auxiliary coil
WX
0~63
Word/D Word
registers
WY
0~63
Word/D Word
registers
WM
0~63
Word/D Word
registers