46 FT-1900R OPERATING MANUAL
MEMORY SKIP SCANNING
When you have some continuously-active channels in memories, you may wish to skip
them for scanning, but still have them available for manual selection.
To mask a memory to be skipped (only) during scanning, use the following procedure:
1. Set the radio to the Memory Recall mode by pressing the
[
D/MR
(
MW
)]
key repeatedly,
as necessary, until “MR” and a channel number appear on the right side of the display.
2. Rotate the DIAL knob to select the Memory Channel to be
skipped during scanning.
3. Press and hold in the
[
MHz
(
SET
)]
key for one second, then
rotate the DIAL knob to select “47 SKIP.”
4. Press the
[
MHz
(
SET
)]
key, then rotate the DIAL knob so
as to select “SKIP”. The current Memory Channel will now
be ignored during scanning. The “ONLY” selection is used for “Preferential Memory
Scan,” described in the next section.
5. Press and hold in the
[
MHz
(
SET
)]
key for one second to save the new setting and exit
to normal operation.
A “SKIP” icon will appear when you recall the “skipped”
memory channel manually.
To re-institute a channel into the scanning loop, select “OFF” in step 4 above, after first
recalling the currently-blocked channel (the “Skipped” channel is accessible via manual
channel selection methods using the DIAL knob in the Memory mode, whether or not it is
locked out of the scanning loop).
SCANNING

Table of Contents

Other manuals for Yaesu FT-1900R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yaesu FT-1900R and is the answer not in the manual?

Yaesu FT-1900R Specifications

General IconGeneral
Frequency Range144-148 MHz
ModeFM
Channels200
Supply Voltage13.8V DC
Antenna Impedance50 ohms
TypeMobile
Output Power50W
Channel Steps5, 10, 12.5, 15, 20, 25, 50 kHz
Sensitivity0.2 μV (12dB SINAD)