1-5
DRIVE TERMINAL WIRE SIZE
MODEL NO.TERMINAL SYMBOL SCREW AWG mm
2
51P51F C003, L1 (R), L2 (S), L3 (T), , ⊕1, ⊕ 2, B1, B2, T1 (U), M4 14-10 2 - 5.5
52P21F C004 T2 (V), T3 (W)
53P71F C006 L1 (R), L2 (S), L3 (T), , ⊕ 1, ⊕ 2, B1, B2, T1 (U), M4 14-10 2 - 5.5
T2 (V), T3 (W)
12-10 3.5-5.5
55P51F C010 L1 (R), L2 (S), L3 (T), , ⊕1, ⊕ 2, B1, B2, T1 (U), M4 12-10 3.5-5.5
T2 (V), T3 (W)
57P51F C012 L1 (R), L2 (S), L3 (T), , ⊕1, ⊕ 2, B1, B2, T1 (U), M4 10 5.5
T2 (V), T3 (W)
12-10 3.5-5.5
50111F C017 L1 (R), L2 (S), L3 (T), , ⊕ 1, ⊕ 2, B1, B2, T1 (U), M5 10-6 5.5-14
T2 (V), T3 (W)
M6
50151F C022 L1 (R), L2 (S), L3 (T), , ⊕ 1, ⊕ 2, B1, B2, T1 (U), M5 8-6 8-14
T2 (V), T3 (W)
M6 10-6 5.5-14
50181F C027 L1 (R), L2 (S), L3 (T),
,
⊕ 1, B1, B2, T1 (U), M6 8-6 8-14
50221F C032 T2 (V), T3 (W)
◆ 10-6 5.5-14
l
1 (r),
l
2(
s
) M4 14 - 10 2 - 5.5
50301F C041 L1 (R), L2 (S), L3 (T),
,
⊕1, T1 (U), T2 (V), T3 (W) M8 6-1/0 14-50
◆ 8-2 8-30
l
1 (r),
l
2(
s
) M4 14 - 10 2 - 5.5
50371F C052 L1 (R), L2 (S), L3 (T),
,
⊕1, T1 (U), T2 (V), T3 (W) M8 4-1/0 22-50
◆ 8-2 8-30
l
1 (r),
l
2(
s
) M4 14 - 10 2 - 5.5
50451F C062 L1 (R), L2 (S), L3 (T),
,
⊕1, T1 (U), T2 (V), T3 (W) M8 3-1/0 30-50
◆ 8-2 8-30
l
1 (r),
l
2(
s
) M4 14 - 10 2 - 5.5
50551F C077 L1 (R), L2 (S), L3 (T),
,
⊕1, T1 (U), T2 (V), T3 (W) M8 2-1/0 30-50
◆ 6-2 22-30
l
1 (r),
l
2(
s
) M4 14 - 10 2 - 5.5
50751F C099 L1 (R), L2 (S), L3 (T),
,
⊕1, T1 (U), T2 (V), T3 (W) M8 2/0-1/0 50-60
◆ 4-2 22-30
l
1 (r),
l
2(
s
) M4 14 - 10 2 - 5.5
50900F C130 L1 (R), L2 (S), L3 (T),
,
⊕1, T1 (U), T2 (V), T3 (W) M10 3/0-300 80-150
◆ 4-2/0 22-60
l
1 (r),
l
2(
s
) M4 14 - 10 2 - 5.5
51100F C172 L1 (R), L2 (S), L3 (T),
,
⊕1, T1 (U), T2 (V), T3 (W) M12 300-400 150-200
◆ 4-2/0 22-60
l
1 (r),
l
2(
s
) M4 14 - 10 2 - 5.5
51600F C200 L1 (R), L2 (S), L3 (T),
,
⊕1, T1 (U), T2 (V), T3 (W) M12 350-400 180-200
◆ 3-2/0 30-60
l
1 (r),
l
2(
s
) M4 14 - 10 2 - 5.5
Section C. 600V
NEW DRIVE OLD DRIVE
TERMINAL
WIRE SIZE
MODEL NO. MODEL NO.
TERMINAL SYMBOL
CIMR-G5M GPD515C–
SCREW
AWG mm
2
◆Indicates terminal uses a pressure lug.
* Consult local electrical codes for wire sizing requirements.
Table 1-1. Typical Wire Sizing For Main Circuit - Continued*