11 Drive Control and Programming
72 YASKAWA TOEPC7106171FD FP605 DRIVE INSTALLATION & PRIMARY OPERATION
No.
(Hex.)
Name Description
E2-01
(030E)
Motor Rated Current (FLA)
Sets the motor rated current in amps.
E2-11
(0318)
Motor Rated Power
Sets the motor rated output in the units from o1-58 [Motor Power Unit Selection].
H1-01 - H1-08
(0438, 0439, 0400 -
0405)
Term S1 to S8 Function Selection
Sets the functions for MFDI terminals S1 to S8.
H2-01
(040B)
Term M1-M2 Function Selection
Sets the function for MFDO terminal M1-M2.
H2-02
(040C)
Term M3-M4 Function Selection
Sets the function for MFDO terminal M3-M4.
H2-03
(040D)
Term MD-ME-MF Function
Selection
Sets the function for MFDO terminal MD-ME-MF.
H3-01
(0410)
Terminal A1 Signal Level Select
Sets the input signal level for MFAI terminal A1.
0 : 0 to 10V (Lower Limit at 0)
2 : 4 to 20 mA
3 : 0 to 20 mA
H3-02
(0434)
Terminal A1 Function Selection
Sets a function for MFAI terminal A1.
H3-03
(0411)
RUN
Terminal A1 Gain Setting
Sets the gain of the analog signal input to MFAI terminal A1.
H3-04
(0412)
RUN
Terminal A1 Bias Setting
Sets the bias of the analog signal input to MFAI terminal A1.
H3-05
(0413)
Terminal A3 Signal Level Select
Sets the input signal level for MFAI terminal A3.
0 : 0-10V (Lower Limit at 0)
2 : 4 to 20 mA
3 : 0 to 20 mA
H3-06
(0414)
Terminal A3 Function Selection
Sets the function for MFAI terminal A3.
H3-07
(0415)
RUN
Terminal A3 Gain Setting
Sets the gain of the analog signal input to MFAI terminal A3.
H3-08
(0416)
RUN
Terminal A3 Bias Setting
Sets the bias of the analog signal input to MFAI terminal A3.
H3-09
(0417)
Terminal A2 Signal Level Select
Sets the input signal level for MFAI terminal A2.
0 : 0-10V (LowLim=0)
2 : 4 to 20 mA
3 : 0 to 20 mA
H3-10
(0418)
Terminal A2 Function Selection
Sets the function for MFAI terminal A2.
H3-11
(0419)
RUN
Terminal A2 Gain Setting
Sets the gain of the analog signal input to MFAI terminal A2.
H3-12
(041A)
RUN
Terminal A2 Bias Setting
Sets the bias of the analog signal input to MFAI terminal A2.
H3-13
(041B)
Analog Input FilterTime Constant
Sets the time constant for primary delay filters on MFAI terminals.
V/f
OLV/PM OLV/PM
EZOLV
V/f
OLV/PM OLV/PM
EZOLV
V/f
OLV/PM OLV/PM
EZOLV
V/f
OLV/PM OLV/PM
EZOLV
V/f
OLV/PM OLV/PM
EZOLV
V/f
OLV/PM OLV/PM
EZOLV
V/f
OLV/PM OLV/PM
EZOLV
V/f
OLV/PM OLV/PM
EZOLV
V/f
OLV/PM OLV/PM
EZOLV
V/f
OLV/PM OLV/PM
EZOLV
V/f
OLV/PM OLV/PM
EZOLV
V/f
OLV/PM OLV/PM
EZOLV
V/f
OLV/PM OLV/PM
EZOLV
V/f
OLV/PM OLV/PM
EZOLV
V/f
OLV/PM OLV/PM
EZOLV
V/f
OLV/PM OLV/PM
EZOLV
V/f
OLV/PM OLV/PM
EZOLV
V/f
OLV/PM OLV/PM
EZOLV
V/f
OLV/PM OLV/PM
EZOLV