EasyManua.ls Logo

YASKAWA GA50C4004ABA - Page 191

YASKAWA GA50C4004ABA
794 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Standards Compliance
5
5.3 UL Standards
YASKAWA SIEPC71061753C GA500 Technical Manual 191
Model Terminal
Recomm. Gauge
AWG, kcmil
Applicable Gauge
AWG, kcmil
Wire Stripping
Length
*1
mm
Terminal Screw
Size and Shape
Tightening Torque
Nm (lbfin)
B012
L/L1, N/L2 8 14 - 8 10
M4
1.5 - 1.7
(13.5 - 15)
U/T1, V/T2, W/T3 12 14 - 10 10
M4
1.5 - 1.7
(13.5 - 15)
-, +1 8 14 - 8 10
M4
1.5 - 1.7
(13.5 - 15)
B1, B2 14 14 - 12 10
M4
1.5 - 1.7
(13.5 - 15)
10
*2
14 - 10
*2
-
M4
1.2 - 1.5
(10.6 - 13.3)
B018
L/L1, N/L2 8 12 - 6 10
M4
1.5 - 1.7
(13.5 - 15)
U/T1, V/T2, W/T3 10 14 - 8 10
M4
1.5 - 1.7
(13.5 - 15)
-, +1 8 12 - 6 10
M4
1.5 - 1.7
(13.5 - 15)
B1, B2 14 14 - 12 10
M4
1.5 - 1.7
(13.5 - 15)
8
*2
12 - 8
*2
-
M5
2.0 - 2.5
(17.7 - 22.1)
*1 Remove insulation from the ends of wires to expose the length of wire shown.
*2 If you turn on the internal EMC filter, the leakage current of the drive will be more than 3.5 mA. Use the closed-loop crimp terminals
to connect a protective ground wire that has a minimum cross-sectional area of 10 mm
2
(copper wire).
Three-Phase 200 V Class
Model Terminal
Recomm. Gauge
AWG, kcmil
Applicable Gauge
AWG, kcmil
Wire Stripping
Length
*1
mm
Terminal Screw
Size and Shape
Tightening Torque
Nm (lbfin)
2001
R/L1, S/L2, T/L3 14 14 6.5
M3
0.5 - 0.6
(4.4 - 5.3)
U/T1, V/T2, W/T3 14 14 6.5
M3
0.5 - 0.6
(4.4 - 5.3)
-, +1, +2 14 14 6.5
M3
0.5 - 0.6
(4.4 - 5.3)
B1, B2 14 14 6.5
M3
0.5 - 0.6
(4.4 - 5.3)
14
*2
14
*2
-
M3.5
0.8 - 1.0
(7.1 - 8.9)
2002
R/L1, S/L2, T/L3 14 14 6.5
M3
0.5 - 0.6
(4.4 - 5.3)
U/T1, V/T2, W/T3 14 14 6.5
M3
0.5 - 0.6
(4.4 - 5.3)
-, +1, +2 14 14 6.5
M3
0.5 - 0.6
(4.4 - 5.3)
B1, B2 14 14 6.5
M3
0.5 - 0.6
(4.4 - 5.3)
14
*2
14
*2
-
M3.5
0.8 - 1.0
(7.1 - 8.9)
2004
R/L1, S/L2, T/L3 14 14 6.5
M3
0.5 - 0.6
(4.4 - 5.3)
U/T1, V/T2, W/T3 14 14 6.5
M3
0.5 - 0.6
(4.4 - 5.3)
-, +1, +2 14 14 6.5
M3
0.5 - 0.6
(4.4 - 5.3)
B1, B2 14 14 6.5
M3
0.5 - 0.6
(4.4 - 5.3)
14
*2
14
*2
-
M3.5
0.8 - 1.0
(7.1 - 8.9)