5 Conditions
YASKAWA TOEP C710617 0SB YASKAWA AC Drive GA500 Installation Manual 17
Normal Duty Rating (ND)
Table 5.11 Single-Phase 200 V Class (Finless-Type Drive)
Drive Model
Rated Output
Current
(A)
Carrier
Frequency
(kHz)
Drive Watt Loss (W)
Interior Unit
Loss
Heatsink Plate Loss
(P
Loss
)
Total
Loss
B001 1.2 2 8 6 14
B002 1.9 2 14 11 25
B004 3.5 2 14 17 31
B006 6.0 2 17 26 43
B010 9.6 2 36 50 86
B012 12.2 2 48 60 108
Table 5.12 Three-Phase 200 V Class (Finless-Type Drive)
Drive Model
Rated Output
Current
(A)
Carrier
Frequency
(kHz)
Drive Watt Loss (W)
Interior Unit
Loss
Heatsink Plate Loss
(P
Loss
)
Total
Loss
2001 1.2 2 7 5 12
2002 1.9 2 9 9 18
2004 3.5 2 11 16 27
2006 6 2 14 25 39
2008 8 2 18 37 55
2010 9.6 2 25 51 76
2012 12.2 2 30 61 91
2018 17.5 2 35 82 117
2021 21 2 52 111 163
2030 30 2
59 175 234
2042 42 2
101 250 351
2056 56 2
127 357 484
2070 70 2
202 455 657