F7-04 IP Address 4
90: Sets the fourth significant octet
(020is the default value)
Example: 192.168.001.090
F7-13 Address Mode at Startup
0: Static
1: BOOTP
2: DHCP
O1-03 Frequency Display Unit Selection 1 : 0.01% units
F7-03 : 208
F7-04 : 090 (If multiple drives are present, see note at bottom.)
F7-13 : 00
O1-03 : 1 on release later than 16161
B1-01 : 3
B1-02 : 3
B1-08 : 1
F6-01 : 0
F6-03 : 0
F6-14 : 1 (Cannot be changed from the front panel. Use Drive Wizard for this parameter)
For a A1000 or a GA500 or a GA800, also update the following parameters:
H5-11 : 1
If there is a delayed safety relay (knob or switches on the front of the safety relay), you will need to
set up the following:
(BOM Example: )
H1-07: 17
C1-09: 4 (Or to your deceleration time)
If there is just a standard safety relay (no knob and no switches on the front of the safety relay),
set these parameters:
(BOM Example: )
H1-07: (Default)
C1-09: (Default)
The six parameters below are usually set by Mach (sometimes).