(4) Deleting program number
4. 7.1 OUTPUTTING PART PROGRAM TO PAPER TAPE
A program number is deleted by the following
operations:
a. Select the EDIT mode.
b. Display the registered program No. of
PROG function or ALM function.
C. Depress the PROG function key.
do Depress “O” key and key-in the program
number.
e. Depress the ERASE key.
The keyed–in program number and the cor-
responding part program are deleted.
(5) Deleting allprogram numbers
All program numbers are deleted by the
following operations:
a.
Select the EDIT mode.
b. Depress the PROG function key or ALM
function key.
c. Keyin O, -9999.
d. Depress the ERASE key.
All registered program numbers and part
programs are deleted. However, only pro-
g“ram number “ O“
is newly registered with
EOB not deleted.
4.7 PART PROGRAM AND NC DATA OUTPUT
OPERATIONS
The following data, which are stored in the NC
internal memory, may be sent to the external
equipment through the data input /output iter–
face (option) :
. Part program
. Tool offset value
. Setting data and parameter
When the external equipment has the tape
punch feature, the data may be punched out;
when it has the print feature, the data may be
printed out.
For the methods of setting the
input /output equipment (setting #6003) and the
baud rate (parameters #6026 through #6029)
through this data input /output interface, refer
to “YASNAC-LX 3 Maintenance Manual. “
(1) The part program of the designated program
number is punched out by the following
operations :
a. Connect the external equipment such as
the tape puncher to the NC via the data
input /output interface.
b. Make the external equipment relay for
operation.
c.
Power on the NC.
d. Select the EDIT mode.
e. Depress the PROG function key.
f.
Check to see if the external equipment is
ready.
g.
Depress the RESET key.
h. Depress “O” key and key in program number .
i.
Depress the OUT key.
The part program of the keyed-in program
number is output to the external equipment.
If it is a tape puncher, tape punch is per-
formed.
When the output of the part pro-
gram is completed, the tape puncher stops
automatically.
During the output of data,
!!OUT” is flashing.
j. To discontinue the punch out operation,
depress the RESET key. However, the
discontinued operation cannot be resumed.
Go back to f. and repeat the operations all
over again.
Note :
When RESET, OUT are operated without
keying in the program number, the part program
of the currently displayed program number is
outputted.
(2) Punch out of all part programs
AH registered part programs may be output
to the external equipment by the above
operations except that
O-9999 mustbe
keyed in the operation of h.
AH part programs stored in the memory are
output (punched out, etc. ) consecutively.
183