Control Circuit Terminal Block Functions
Drive parameters determine which functions apply to the multi-function digital inputs (S1 to S7), multi-function digital outputs
(M1 to M6), multi-function analog inputs (A1 and A2), and multi-function analog monitor output (FM, AM). The default
setting is listed next to each terminal in Figure i.10 on page 17.
WARNING! Sudden Movement Hazard. Always check the operation and wiring of control circuits after being wired. Operating a drive with
untested control circuits could result in death or serious injury.
WARNING! Sudden Movement Hazard. Confirm the drive I/O signals and external sequence before starting test run. Setting parameter
A1-06 may change the I/O terminal function automatically from the default setting. Failure to comply may result in death or serious injury.
n
Input Terminals
Table i.7 lists the input terminals on the drive. Text in parenthesis indicates the default setting for each multi-function input.
Table i.7 Control Circuit Input Terminals
Type No. Terminal Name (Function) Function (Signal Level) Default Setting
Multi-Function
Digital Inputs
S1
Multi-function input 1
(Closed: Forward run, Open: Stop)
Photocoupler
24 Vdc, 8 mA
Set the wire jumper to select between sinking, sourcing mode, and the
power supply. Refer to Sinking/Sourcing Mode Switch for Digital
Inputs on page 34.
S2
Multi-function input 2
(Closed: Reverse run, Open: Stop)
S3
Multi-function input 3
(External fault, N.O.)
S4
Multi-function input 4
(Fault reset)
S5
Multi-function input 5
(Multi-step speed reference 1)
S6
Multi-function input 6
(Multi-step speed reference 2)
S7
Multi-function input 7
(Jog reference)
SC Multi-function input common Multi-function input common
SP Digital input power supply +24 Vdc 24 Vdc power supply for digital inputs, 150 mA max
NOTICE: Do not jumper or short terminals SP and SN. Failure to
comply will damage the drive.
SN Digital input power supply 0 V
Frequency
Reference
Inputs
+V Power supply for analog inputs 10.5 Vdc (max allowable current 20 mA)
A1
Multi-function analog input 1
(Frequency reference bias)
0 to 10 Vdc/100% (input impedance: 20 kΩ)
4 to 20 mA/100%, 0 to 20 mA/100% (input impedance: 250 Ω)
Voltage or current input must be selected by Jumper S1 and H3-01.
A2
Multi-function analog input 2
(Frequency reference bias)
0 to 10 Vdc/100% (input impedance: 20 kΩ)
4 to 20 mA/100%, 0 to 20 mA/100% (input impedance: 250 Ω)
Voltage or current input must be selected by Jumper S1 and H3-09.
AC Frequency reference common 0 V
FE Ground for shielded lines and option cards
i.4 Electrical Installation
28
YASKAWA ELECTRIC TOEP C710616 54A YASKAWA AC Drive - Z1000 Quick Start Guide