IM 01E20D01-01E
10th June 2012 6-33 Corrected the sentence of /MU.
6-34 Changed the selectable range of flow rate span for optional code
"SC".
6-43 Correced the figure.
6-49 Corrected the value of ød of CG1.
6-53 Moved the item of Recommended Gaskets Between Flowtubes And
User's Flanges to P6-8.
8-1 Added the year to applicable standard numbers of CENELEC ATEX.
8-5 Added the "Process Sealing Certification".
8-8 Changed the certificate numbers of TIIS Flameproof.
11th Oct. 2014 1-2 to 1-4 1.1 (1), (3), (4) Added and corrected the warning notes for specification
conditions.
1.3 Deleted the description for sizes 500 to 2600mm (20 to 104 inch).
1-5 1.4 Corrected the description.
2-1 2.1 Deleted the description for sizes 500 to 2600mm (20 to 104 inch).
3-1 3.1 (3) Corrected the length of straight run, when installing two or more
magnetic flowmeters.
3-3 3.2.1 (1) Added the horizontal position figure in Figure 3.2.1.
Corrected the vertical position figure in Figure 3.2.1.
Corrected the caution notes for transportation.
3-5 3.3.1 Corrected the Table 3.3.1.
3-8 to 3-9 3.3.2 (4) Corrected the tightening torque values for ceramics lining type in
Table 3.3.4 to Table 3.3.6.
3-11 to 3-13 3.3.3 (4) Corrected the tightening torque values for ceramics lining type in
Table 3.3.7 to Table 3.3.9.
3-19 3.3.5 Deleted the description for sizes 500 to 2600mm (20 to 104 inch).
Added the PTFE-sheathed nonasbestos gasket in Table 3.3.16.
Corrected the inner diameter of grounding ring, outer diameter for
effective sealing and recommended inner diameter of gasket in
Table 3.3.16.
4-1 4.1.1 Corrected the caution notes for wiring ports.
4-2 4.1.3 Corrected the important notes.
Corrected the Figure 4.1.1.
4-4 4.1.4 (3) Changed the numbers of IEC in warning note.
4-6 4.1.4 (6) Corrected the value of maximum load resistance in Figure 4.1.10.
Corrected the Figure 4.1.12.
4-8 4.2.1 Deleted the description for sizes 500 to 2600mm (20 to 104 inch).
4-10 4.2.3 Corrected the important notes for wiring ports.
Corrected the Figure 4.2.4.
4-11 4.2.3 (2) Corrected the Figure 4.2.5.
Corrected the Figure 4.2.6.
4-11 to 4-14 4.2.4 Deleted the description for sizes 500 to 2600mm (20 to 104 inch).
Corrected the Figure 4.2.15.
5-1 5.1 Deleted the description for sizes 500 to 2600mm (20 to 104 inch).
5-9 5.5.2 Corrected the notes for the write protect switch.
5.8 Added the maintenance of the LCD display.
6-1 to 6-47 6 Deleted the description for sizes 500 to 2600mm (20 to 104 inch).
Added the values of withstand voltage for optional codes WT1 and
WT2.
Added the number of EN standard in Safety Requirement Standards.
Added the applicable model for optional code K1.
Added the optional codes E01, WT1, WT2, PM1, PM2, PM3 and PT.
Added the parts number in the table of flameproof packing adapter
for TIIS flameproof type.
7-1 7 Deleted the description for sizes 500 to 2600mm (20 to 104 inch).
8-4 8.2 (2) Added the figure for electrical connection in FM.
8-4 to 8-5 8.2 (3), (4), (5) Added the warning notes in FM.
8-5 8.3 (1) Changed the number of Applicable Standard in CSA.
8-10 to 8-11 8.5 (2) Added the parts number in the table of flameproof packing adapter
for TIIS flameproof type.
Added the description for wiring ports.
Edition Date Page Revised Item