4-34
IM DL350-17EN
:ANALysis:HARMonic:LRMS<x>?
Function Queries all harmonic RMS analysis settings.
Syntax
:ANALysis:HARMonic:LRMS<x>?
<x> = 1 to 8
:ANALysis:HARMonic:LRMS<x>:HYSTeres
is
Function Sets or queries the frequency detection hysteresis
of harmonic RMS analysis.
Syntax
:ANALysis:HARMonic:LRMS:
HYSTeresis {HIGH|LOW|MIDDle}
:ANALysis:HARMonic:LRMS:HYSTeresis?
<x> = 1 to 8
Example
:ANALYSIS:HARMONIC:LRMS1:
HYSTERESIS LOW
:ANALYSIS:HARMONIC:LRMS2:HYSTERESIS?
-> :ANALYSIS:HARMONIC:LRMS2:
HYSTERESIS LOW
:ANALysis:HARMonic:LRMS<x>:MODE
Function Sets or queries the computation mode of
harmonic RMS analysis.
Syntax
:ANALysis:HARMonic:LRMS:
MODE {<Boolean>}
:ANALysis:HARMonic:LRMS:MODE?
<x> = 1 to 8
Example
:ANALYSIS:HARMONIC:LRMS1:MODE 1
:ANALYSIS:HARMONIC:LRMS2:MODE?
-> :ANALYSIS:HARMONIC:LRMS2:MODE 1
:ANALysis:HARMonic:LRMS<x>:RESult?
Function Queries all analysis results related to harmonic
RMS analysis.
Syntax
:ANALysis:HARMonic:LRMS<x>:RESult?
<x> = 1 to 8
:ANALysis:HARMonic:LRMS<x>:RESult:FR
EQuency?
Function Queries the fundamental frequency of harmonic
RMS analysis.
Syntax
:ANALysis:HARMonic:LRMS<x>:RESult:
FREQuency?
<x> = 1 to 8
:ANALysis:HARMonic:LRMS<x1>:RESult:P
HIK<x2>?
Function Queries the phase angle of each harmonic of
harmonic RMS analysis.
Syntax
:ANALysis:HARMonic:LRMS<x1>:RESult:
PHIK<x2>?
<x1> = 1 to 8
<x2> = 1 to 40
:ANALysis:HARMonic:LRMS<x1>:RESult:R
HDFk<x2>?
Function Queries the percentage content of each harmonic
of harmonic RMS analysis.
Syntax
:ANALysis:HARMonic:LRMS<x1>:RESult:
RHDFk<x2>?
<x1> = 1 to 8
<x2> = 1 to 40
:ANALysis:HARMonic:LRMS<x>:RESult:R
MS?
Function Queries all rms values of harmonic RMS analysis.
Syntax
:ANALysis:HARMonic:LRMS<x>:RESult:
RMS?
<x> = 1 to 8
:ANALysis:HARMonic:LRMS<x1>:RESult:R
MSK<x2>?
Function Queries the rms value of each harmonic of
harmonic RMS analysis.
Syntax
:ANALysis:HARMonic:LRMS<x1>:RESult:
RMSK<x2>?
<x1> = 1 to 8
<x2> = 1 to 40
:ANALysis:HARMonic:LRMS<x>:RESult:TH
DCsa?
Function Queries the total distortion (CSA) of harmonic
RMS analysis.
Syntax
:ANALysis:HARMonic:LRMS<x>:RESult:
THDCsa?
<x> = 1 to 8
:ANALysis:HARMonic:LRMS<x>:RESult:TH
DIec?
Function Queries the total distortion (IEC) of harmonic
RMS analysis.
Syntax
:ANALysis:HARMonic:LRMS<x>:RESult:
THDIec?
<x> = 1 to 8