EasyManuals Logo

YOKOGAWA DL350 User Manual

YOKOGAWA DL350
215 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #68 background imageLoading...
Page #68 background image
4-41
IM DL350-17EN
Commands
1
2
3
4
5
App
Index
:CHANnel<x>:CAN?
Function Queries all settings of a module that can monitor
CAN bus signals.
Syntax
:CHANnel<x>:CAN?
CAN Bus Monitor Module (720240) or
the CAN/CAN FD monitor module (720242)
<x> = 1 to 4
CAN & LIN Bus Monitor Module (720241)
<x> = 1, 3
:CHANnel<x>:CAN:OSOut?
Function Queries all one-shot output settings of the
specified port of a module that can monitor CAN
bus signals.
Syntax
:CHANnel<x>:CAN:OSOut?
CAN Bus Monitor Module (720240) or
the CAN/CAN FD monitor module (720242)
<x> = 1 to 4
CAN & LIN Bus Monitor Module (720241)
<x> = 1, 3
:CHANnel<x1>:CAN:OSOut:DATA<x2>
Function Sets or queries the one-shot output data of the
specified port of a module that can monitor CAN
bus signals.
Syntax
:CHANnel<x1>:CAN:OSOut:
DATA<x2> {<String>}
For the CAN bus monitor module (720240)
<x1> = 1 to 4, <x2> = 1 to 8
For the CAN/CAN FD monitor module (720242)
<x1> = 1 to 4, <x2> = 1 to 64
For the CAN & LIN monitor module (720241)
<x1> = 1, 3, <x2> = 1 to 8
<String> = “0” to “FF”
Example
:CHANNEL3:CAN:OSOUT:DATA1 "FF"
:CHANNEL3:CAN:OSOUT:DATA1?
-> :CHANNEL3:CAN:OSOUT:DATA1 "FF"
Description If a string outside the range is specified, error
151, “Invalid string data,” will occur.
:CHANnel<x>:CAN:OSOut:DLC (Data
Length Code)
Function Sets or queries the one-shot output data length
of the specified port of a module that can monitor
CAN bus signals.
Syntax
:CHANnel<x>:CAN:OSOut:DLC {<NRf>}
CAN Bus Monitor Module (720240) or
the CAN/CAN FD monitor module (720242)
<x> = 1 to 4
CAN & LIN Bus Monitor Module (720241)
<x> = 1, 3
<NRf> = 0 to 15
Example
:CHANNEL3:CAN:OSOUT:DLC 15
:CHANNEL3:CAN:OSOUT:DLC?
-> :CHANNEL3:CAN:OSOUT:DLC 15
:CHANnel<x>:ACCL:UNIT
Function Sets or queries the unit string when the coupling
of an acceleration/voltage module is set to
acceleration.
Syntax
:CHANnel<x>:ACCL:UNIT {<String>}
:CHANnel<x>:ACCL:UNIT?
<x> = 1 to 4
<String> = Up to 4 characters
Example
:CHANNEL1:ACCL:UNIT “m/s2”
:CHANNEL1:ACCL:UNIT?
-> :CHANNEL1:ACCL:UNIT “m/s2”
:CHANnel<x>:ACCL:VARiable
Function Sets or queries the scale setting mode when the
coupling of an acceleration/voltage module is set
to acceleration.
Syntax
:CHANnel<x>:ACCL:
VARiable {<Boolean>}
:CHANnel<x>:ACCL:VARiable?
<x> = 1 to 4
Example
:CHANNEL1:ACCL:VARIABLE 0
:CHANNEL1:ACCL:VARIABLE?
-> :CHANNEL1:ACCL:VARIABLE 0
:CHANnel<x>:ACCL:ZOOM
Function Sets or queries the vertical zoom factor when the
coupling of an acceleration/voltage module is set
to acceleration.
Syntax
:CHANnel<x>:ACCL:ZOOM {<NRf>}
:CHANnel<x>:ACCL:ZOOM?
<x> = 1 to 4
<NRf> = 0.5, 0.556, 0.625, 0.667, 0.714, 0.8,
0.833, 1, 1.11, 1.25, 1.33, 1.43, 1.67, 2,
2.22, 2.5, 3.33, 4, 5, 6.67, 8, 10, 12.5,
16.7, 20, 25, 40, 50
Example
:CHANNEL1:ACCL:ZOOM 1.000
:CHANNEL1:ACCL:ZOOM?
-> :CHANNEL1:ACCL:ZOOM 1.000
4.6 CHANnel Group

Other manuals for YOKOGAWA DL350

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DL350 and is the answer not in the manual?

YOKOGAWA DL350 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDL350
CategoryRecording Equipment
LanguageEnglish

Related product manuals