EasyManuals Logo

YOKOGAWA DL350 User Manual

YOKOGAWA DL350
215 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #82 background imageLoading...
Page #82 background image
4-55
IM DL350-17EN
Commands
1
2
3
4
5
App
Index
:CHANnel<x>:FREQ:VDIV
Function Sets or queries the Value/Div setting of a
frequency module.
Syntax
:CHANnel<x>:FREQ:VDIV {<NRf>|
<Frequency>|<Time>}
:CHANnel<x>:FREQ:VDIV?
<x> = 1 to 4
{<NRf>|<Frequency>|<Time>}
= See the DL350
Features Guide for this information.
Example
:CHANNEL1:FREQ:VDIV 20
:CHANNEL1:FREQ:VDIV?
-> :CHANNEL1:FREQ:VDIV 20
:CHANnel<x>:FREQ:ZOOM
Function Sets or queries the vertical zoom factor of a
frequency module.
Syntax
:CHANnel<x>:FREQ:ZOOM {<NRf>}
:CHANnel<x>:FREQ:ZOOM?
<x> = 1 to 4
<NRf> = 0.33, 0.4, 0.5, 0.556, 0.625, 0.667, 0.714,
0.8, 0.833, 1, 1.11, 1.25, 1.33, 1.43, 1.67,
2, 2.22, 2.5, 3.33, 4, 5, 6.67, 8, 10, 12.5,
16.7, 20, 25, 40, 50, 100
Example
:CHANNEL1:FREQ:ZOOM 1
:CHANNEL1:FREQ:ZOOM?
-> :CHANNEL1:FREQ:ZOOM 1
:CHANnel<x>:LABel
Function Sets or queries the waveform label of a channel.
Syntax
:CHANnel<x>:LABel {<String>}
:CHANnel<x>:LABel?
<x> = 1 to 4
<String> = Up to 16 characters
Example
:CHANNEL1:LABEL “ABC”
:CHANNEL1:LABEL?
-> :CHANNEL1:LABEL “ABC”
Description This setting is invalid for a module that has sub
channels, but it is valid for logic modules.
:CHANnel<x>:LIN?
Function Queries all settings of a module that can monitor
LIN bus signals.
Syntax
:CHANnel<x>:LIN?
<x> = 2, 4
:CHANnel<x1>:LIN:FRAMe<x2>?
Function Queries all LIN bus signal frame settings.
Syntax
:CHANnel<x1>:LIN:FRAMe<x2>?
<x1> = 2, 4
<x2> = 1 to 64
:CHANnel<x1>:LIN:FRAMe<x2>:CHECksum
Function Sets or queries the checksum mode of LIN bus
signal frames.
Syntax
:CHANnel<x1>:LIN:FRAMe<x2>:
CHECksum {CLASsic|ENHanced}
:CHANnel<x1>:LIN:FRAMe<x2>:CHECksum?
<x1> = 2, 4
<x2> = 1 to 64
Example
:CHANNEL4:LIN:FRAME1:
CHECKSUM CLASSIC
:CHANNEL4:LIN:FRAME1:CHECKSUM?
-> :CHANNEL4: LIN:FRAME1:
CHECKSUM CLASSIC
Description When FRAMe<x2> = 1, frame ID = 0.
When <x2> = 64, frame ID = 63.
:CHANnel<x1>:LIN:FRAMe<x2>:DLENgth
Function Sets or queries the data length of LIN bus signal
frames.
Syntax
:CHANnel<x1>:LIN:FRAMe<x2>:
DLENgth {<NRf>}
<x1> = 2, 4
<x2> = 1 to 64
<NRf> = 1 to 8
Example
:CHANNEL4:LIN:FRAME1:DLENGTH 8
:CHANNEL4:LIN:FRAME1:DLENGTH?
-> :CHANNEL4:LIN:FRAME1:DLENGTH 8
Description When FRAMe<x2> = 1, frame ID = 0. When <x2>
= 64, frame ID = 63.
:CHANnel<x>:LIN:PORT?
Function Queries all settings of the specified port of a
module that can monitor LIN bus signals.
Syntax
:CHANnel<x>:LIN:PORT?
<x> = 2, 4
4.6 CHANnel Group

Other manuals for YOKOGAWA DL350

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DL350 and is the answer not in the manual?

YOKOGAWA DL350 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDL350
CategoryRecording Equipment
LanguageEnglish

Related product manuals