4-54
IM 04L51B01-01EN
Data Hold
Register
Supplementary Information Data Type
Write a message
(free message)
409205 0: Fixed at 0 when reading
ASCII character string (2
characters)
Up to 35 characters
(except the number of valid
characters is 32)
Ignored for preset messages
Attach a terminator at the
end
| | |
Write a message
(free message)
409221 0: Fixed at 0 when reading
ASCII character string (2
characters)
Up to 35 characters
(except the number of valid
characters is 32)
Ignored for preset messages
Attach a terminator at the
end
Batch, lot number 409301 Lower bytes of the lot
number
32-bit signed integer
409302 Higher bytes of the lot
number
409303 Batch number
Two-character ASCII string
for each register
Up to 32 characters [attach
the terminator '\0' at the end]
16-bit signed integer
| |
409319 Batch number
Two-character ASCII string
for each register
Up to 32 characters [attach
the terminator '\0' at the end]
Batch, lot number (multi
batch support)
409351 Batch name
1 or greater: Batch group
number
16-bit signed integer
409352 Lower bytes of the lot
number
32-bit signed integer
409353 Higher bytes of the lot
number
409354 Batch number
Two-character ASCII string
for each register
Up to 32 characters [attach
the terminator '\0' at the end]
16-bit signed integer
| |
409379 Batch number
Two-character ASCII string
for each register
Up to 32 characters [attach
the terminator '\0' at the end]
Batch Comment (multi batch
support)
409401 Batch comment
1 or greater: Batch group
number
16-bit signed integer
409402 Batch comment number
409403 Comment string
Two-character ASCII string
for each register
Up to 32 characters [attach
the terminator '\0' at the end]
| |
409428 Comment string
Comment string
Two-character ASCII string
for each register
Up to 32 characters [attach
the terminator '\0' at the end]
Continued on next page
4.5 Modbus Function and Register Assignments