EasyManuals Logo

YOKOGAWA GX60 User Manual

YOKOGAWA GX60
590 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #555 background imageLoading...
Page #555 background image
5
All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation
GS 04L52B01-01EN
Nov. 10, 2015-00
• Numberofrecordingchannels;
GP10,GP20-1:Max.50
GP20-2:Max.100
• Maximumnumberofdatavaluesthattheinternal
memorycanstore:400
• Dataformat:Text
ReportData
• Item:Reportateachscheduledtimeofreport
• Target:Measurement(input/outputmodule)/
math/communicationchannels
• Maximumnumberofreportsthattheinternal
memorycanstore:800
• Dataformat:Text
SnapshotData
• Item:Displayedscreenimagedata
• Dataformat:PNG
• Outputdestination:Externalmediumor
communicationoutput
SetupData
• Item:GPsetupdata
• Dataformat:text
• Output/readdestination(forsaving/loading):
Externalmedium
ClockFunctions
• Clock:Withacalendarfunction
• Accuracy:±5ppm(0to50°C),excludingadelay
(of1second,maximum)causedeachtimethe
power is turned on.
• Timedifferencebetweenunits:±2msmax.(time
differencebetweenaGPandI/OBaseUnit
(ExpandableI/O))
• Timesetting:Usingtouchoperation,
communicationcommand,eventactionfunction,
orSNTPclientfunction
• Timeadjustmentmethod:
Limitinwhichthetimeisgraduallyadjusted:
Selectfromtheavailablesettingsbetween5s
and 15 s.
Whethertochangeanout-of-limitoperation
immediatelyorreportitasanerrorcanbe
selected.
Whilememorysampling:Correctsthetimeby1
msforeachsecond.
Whilememoryisstopped:Immediatelychange
thetime.
• DST:Thedate/timeforswitchingbetween
standardtimeandDSTcanbespecied.
• Timezone:SetsthetimedifferencefromGMT.
• Dateformat:Select"YYYY/MM/DD","MM/DD/
YYYY","DD/MM/YYYY"or"DD.MM.YYYY".
MMexpressioncanbeselectedfromthe
numericcharacterorellipsis.Ex.January:01or
Jan
Thedelimitercanbeselectedfrom"/",".","-".
EthernetCommunicationFunctions
• Electricalspecications:ConformstoIEEE802.3
• Connection:Ethernet(10BASE-T/100BASE-TX)
• Max.segmentlength:100m
• Max.connectingconguration:CascadeMax.4
level(10BASE-T),Max.2level(100BASE-TX)
• Connector:RJ-45
• Protocols:TCP,UDP,IP,ICMP,ARP,DHCP,
HTTP, FTP, SMTP, SNTP, Modbus, and
dedicated protocols
• E-mailclient:Automaticallysende-mailat
speciedtimes.
E-mailissentbyeventsasbelow.
- Alarmoccurring/alarmcanceling(Max.50ch)
- Recoverfrompowerfailure
- Report data generating
- Storagemediumerror,FTPclientfunction
error
- Speciedtimeperiod
POPbeforeSMTPandSMTPauthentication
(PLAINandCRAM-MD5)isavailable.
• FTPclient:Automaticallytransferdatalestothe
FTP server.
Applicableles:Displaydata,eventdata,screen
imagedata,reportdata,etc.
• FTPServer:Transferles,deleteles,
manipulatedirectories,andoutputlelistsofthe
G P.
Numberofthesimultaneousconnection:Max.4
• Webserver:GPreal-timemonitoringandsetting
changes/operationscanbeperformedwiththe
Webbrowser.
Numberofthesimultaneousconnection:Max.4
• SNTPclient:InquiresthetimetotheSNTP
server and sets the GP.
• SNTPserver:OutputstheGPtime.
Timeresolution:5ms
• DHCPclient:Automaticallyobtainthenetwork
addresssettingsfromtheDHCPserver.
• Modbusclient:Readsdatafromanotherdevice
and writes to the registers.
Numberofconnectablesever;
GP10,GP20-1:Max.16
GP20-2:Max.32
• Modbusserver:Loadsmeasurementandmath
channel data
Loadsandwritescommunicationchanneldata
Somecontrolcommandssuchasmemorystart
Modbusclient*registeraccesslimitations
*:Required/MCoption
Numberofthesimultaneousconnection:Max.4
• Setting/Measurementserver:Operate,set,and
outputdataoftheGPusingadedicatedprotocol.
Numberofthesimultaneousconnection:Max.4
• DARWINcompatiblecommunicationserver:
SupportssomeDARWINcommands
CommunicationwithGPispossibleusing
DARWINcommunicationcommands.
• Output-relatedcommands:Output
measurement(IO)channeldata,Output
calculation channel data, Output relay status,
Outputthepositionofthedecimalpointforthe
measurement(IO)channel,Outputtheposition
ofthedecimalpointforthecalculationchannel,
Outputtheinformationonsystemconguration
• Setup-relatedcommands:Range,Scaleunit,
Alarm,Time,Movingaverage
• Operation-relatedcommands:Resetalarm,
Resettimer,StartMATHcalculation,Rebuild
system,Initialize,Inputcommunication,Output
communicationDO,Writemessage

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA GX60 and is the answer not in the manual?

YOKOGAWA GX60 Specifications

General IconGeneral
BrandYOKOGAWA
ModelGX60
CategoryVoice Recorder
LanguageEnglish

Related product manuals