EasyManua.ls Logo

YOKOGAWA Rotamass series User Manual

YOKOGAWA Rotamass series
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
User's Manual
IM 01U10B00-00EN-R
IM 01U10B00-00EN-R, 3rd edition, 2018-07-09
ROTA
MASS
Total Insight
Coriolis Mass Flow and Density Meter
General Instruction Manual

Table of Contents

Questions and Answers:

YOKOGAWA Rotamass series Specifications

General IconGeneral
Measurement PrincipleCoriolis
Repeatability±0.05% of rate
Communication ProtocolsHART, FOUNDATION Fieldbus, Modbus
MaterialStainless steel
Power Supply24 V DC, 100-240 V AC depending on model
Process ConnectionFlanged, threaded, or sanitary (varies by model)
Outputs4-20 mA, pulse, frequency
Hazardous Area ApprovalsATEX, IECEx, FM, CSA depending on model
Fluid CompatibilityCompatible with liquids and gases (varies by model)
Enclosure RatingIP67

Summary

Explanation of safety instructions and symbols

Safety

Intended use

Describes the primary functions and applications of the flow meter.

General safety instructions

Product specification

Measuring principle and flow meter design

Explains the Coriolis principle and the meter's physical design.

Installation

Installation instructions

General instructions and warnings for the installation process.

Installation site

Guides on selecting an appropriate and safe location for installation.

Instructions

Installation position

Sensor installation

General installation rules

Essential rules for safe and accurate sensor installation, avoiding noise.

Installation in pipe

Transmitter installation

Installing transmitter on pipe (remote type)

Installation check list

Wiring

General wiring rules

Essential safety rules and precautions for electrical wiring.

Grounding connections and sensor circuits

Connecting cable installation

Connecting the connecting cable to sensor

Connecting the connecting cable to transmitter

Transmitter

Connection terminals

Explains the terminal box layout for power and I/O connections.

Assignment of inputs and outputs

Maps model code positions to I/O terminal assignments for HART.

Power supply

Specifies voltage requirements and power consumption for the device.

Connecting power supply and external devices

Instructions for connecting power and external devices safely.

Wiring check list

Commissioning

System configuration and operation

Default settings

Setting zero point

Performing autozero

Advanced settings

Troubleshooting

Malfunction of operation

Lists common malfunctions and their remedies.

Zero point unstable

Display deviating

Maintenance and repair

Related product manuals