c) Coke oven facility
This facility is used to produce the coke used in the blast furnace.
The O
2
analyzer is used to monitor the exhaust gas from the heater combustion used for destruc-
tive distillation of the coal.
Sample point System type
T0405.EPS
ObjectiveDetector
Flue L2, L3 D1, (D2) Combustion monitoring
F0405.EPS
Dust Fuel
Coking Chamber
Combustion
Chamber
Combustion Chamber
Heat Protection Chamber
Flue
Stack
Rich Gas Tube
Lean Gas Tube
Backstay
Coke oven facility
Temperature: 250 to 350°C
Pressure: 0.1 to 0.3 kPa
Dust: 100 mg/Nm
3
Fuel: Gas