YOKOGAWA ZR802G User Manual

YOKOGAWA ZR802G
241 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Users
Manual
ZR22G and ZR802G
Zirconia Oxygen/Humidity
Analyzer
IM 11M12G01-02EN
IM 11M12G01-02EN
1st Edition

Table of Contents

Other manuals for YOKOGAWA ZR802G

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA ZR802G and is the answer not in the manual?

YOKOGAWA ZR802G Specifications

General IconGeneral
TypeZirconia Oxygen Analyzer
Enclosure RatingIP66
Measurement PrincipleZirconia sensor
ApplicationCombustion control
Output Signal4 to 20 mA DC
Operating Temperature-20 to 55 °C
Power Supply100 to 240 V AC, 50/60 Hz
Response TimeTypically less than 5 seconds (90% response)

Summary

Product Safety and Precautions

Product Safety, Protection, and Modification Guidelines

Essential guidelines for product safety, protection circuits, and prohibition of modifications.

Technical Specifications

Installation Procedures

Piping System Configurations

Wiring and Electrical Connections

Communication and Input Wiring

Communication and Input Wiring

Wiring for communication interfaces (RS485, Ethernet) and contact inputs.

System Components Overview

ZR22G Detector Components

Detailed description of the ZR22G detector and its parts.

Startup and Initial Configuration

Startup Procedure and Pre-checks

Step-by-step startup process including checking connections, valves, and supplying power.

Calibration Modes and Setup

Calibration Modes and Setup

Understanding calibration modes and configuring settings for manual, semi-auto, and auto calibration.

Detailed Data Settings and Configuration

Alarm and Contact Configuration

Configuring alarm thresholds, output actions, and input contact functions for system monitoring.

Calibration Principles and Procedures

Calibration Gas and Step-by-Step Process

Details on calibration gases and a comprehensive guide to performing calibration.

Calibration Modes and Timing Settings

Calibration Modes and Timing Settings

Description of calibration modes and configuring timing parameters like hold and calibration time.

Blow Back and Cell Resistance Measurement

Communication and Data Management

Setting up communication protocols and managing data via SD card for logs and configuration.

Inspection and Maintenance Procedures

Detector Inspection and Maintenance

Procedures for cleaning sensor filter, calibration gas tube, and replacing sensor assembly.

Converter Maintenance and Adjustments

Converter Maintenance and Adjustments

Procedures for replacing converter fuses, cleaning, and adjusting the LCD panel.

Troubleshooting Guide

Fault Identification and Remedies

Identifying fault codes and their remedies for detector and converter errors.

Alarm Conditions and Resolution Steps

Understanding alarm types, causes, and remedies for abnormal conditions.

Specific Alarm Troubleshooting

Specific Alarm Troubleshooting

Detailed remedies for specific alarms like cell voltage, heater temperature, and A/D converter failures.

Addressing Measurement Value Abnormalities