EasyManua.ls Logo

York R-134a - Maintenance Tasks; Parts, Leak, and Pressure Testing

York R-134a
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
JOHNSON CONTROLS
23
SECTION 3 - DIMENSIONS AND WEIGHTS
FORM 160.69-N3
ISSUE DATE: 10/30/2015
3
NOTES:
1. All dimensions are approximate. Certified dimensions are available on
request.
2. For compact water boxes (shown above), determine overall unit length by add-
ing water box depth to tube sheet length.
3. Water nozzles can be located on either end of unit. Add 1/2" to nozzle length
for flanges connections.
4. To determine overall height, add dimension "M" for the appropriate
isolator type.
5. Use of motors with motor hoods may increase overall unit dimensions.
TABLE 1 - DIMENSIONS – K COMPRESSOR UNITS FT.–IN.(MM)
EVAPORATOR - CONDENSER SHELL CODES FT. - IN. (MM)
DIMENSION B-L M-M N-B E-C F-D G-E H-F K-K
A
11'-6"
(3,505)
11'-6"
(3,505)
11'-11"
(3,632)
13'-4"
(4,064)
14'-6"
(4,420)
14'-6"
(4,420)
15'-0"
(4,572)
16'-0"
(4,877)
B
12'-8"
(3,861)
12'-8"
(3,861)
13'-0"
(3,962)
13'-10"
(4,216)
14'-4"
(4,369)
14'-4"
(4,369)
14'-10"
(4,521)
15'-3"
(4,648)
C
2'-8"
(813)
2'-8" (813)
2'-11 1/2"
(902)
3'-5"
(1,041)
3'-9"
(1,143)
3'-9"
(1,143)
4'-0"
(1,219)
4'-0"
(1,219)
D
2'-5 1/2"
(749)
2'-5 1/2"
(749)
2'-5 1/2"
(749)
2'-8"
(813)
3'-1 1/2"
(953)
3'-1 1/2"
(953)
3'-1 1/2"
(953)
3'-4"
(1,016)
E
18'-0"
(5,486)
22'-0"
(6,706)
18'-0"
(5,486)
22'-0"
(6,706)
18'-0"
(5,486)
22'-0"
(6,706)
18'-0"
(5,486)
22'-0"
(6,706)
F
2'-3/4"
(629)
2'-3/4"
(629)
2'-1 11/16"
(660)
2'-13/16"
(635)
2'-3"
(686)
2'-3"
(686)
2'-3 9/16"
(699)
2'-3 9/16"
(699)
G
1'-4 1/2"
(419)
1'-4 1/2"
(419)
1'-5 11/16"
(445)
1'-4 3/16"
(413)
1'-6 1/4"
(464)
1'-6 1/4"
(464)
1'-6 7/8"
(483)
1'-6 7/8"
(483)
H
0'-11 11/16"
(305)
0'-11 11/16"
(305)
0'-11"
(279)
0'-11"
(279)
1'-2 9/16"
(368)
1'-2 9/16"
(368)
1'-3 9/16"
(394)
1'-4 3/16"
(413)
J
1'-7 3/8"
(492)
1'-7 3/8"
(492)
1'-7 1/2"
(495)
1'-7 3/8"
(492)
2'-1 1/2"
(648)
2'-1 1/2"
(648)
2'-2"
(660)
2'-13/16"
(635)
L
5'-1 1/2"
(1,562)
5'-1 1/2"
(1,562)
5'-5"
(1,651)
6'-1"
(1,854)
6'-10 1/2"
(2,096)
6'-10 1/2"
(2,096)
7'-1 1/2"
(2,172)
7'-4"
(2,235)
N
13'-3"
(4039)
13'-3"
(4039)
14'-5"
(4395)
15'-10"
(4826)
17'
(5182)
N/A N/A N/A
ADDITIONAL OPERATING HEIGHT
CLEARANCE TO FLOOR
TYPE OF CHILLER MOUNTING M
NEOPRENE PAD ISOLATORS
1-3/4"
(44)
SPRING ISOLATORS 1" DEFLECTION
1"
(25)
DIRECT MOUNT
3/4"
(19)

Table of Contents

Other manuals for York R-134a

Related product manuals