56 / 58
Identificazione: MD-AL-GI-00
Rev. 4.0 del 31.01.18 - Applicazione: GID
Manual of 11/06/2019 Rev. 1.8 “User Manual for 3000SP storage inverter
ID104
BatOTD
Over-temperature
protection of battery
discharge
ID106-ID107 are battery errors.
Check the conditions of installation and ventilation of
the battery. Alternatively, reduce the charge and
discharge current value set.
If the error persists, contact Technical Support.
ID105
BatOTC
Over-temperature
protection of battery
charge
ID106
BatUTD
Under-temperature
protection of battery
discharge
ID106-ID107 are battery errors.
Check the installation and ventilation conditions of the
battery.
If the error persists, contact Technical Support.
ID107
BatUTC
Under-temperature
protection of battery
charge
8.2. Maintenance
Inverters generally do not require daily or routine maintenance. In any case, for proper long-term operation
of the inverter, make sure that the heatsink for cooling the inverter has enough space to ensure adequate
ventilation and that it is not obstructed by dust or other items.
Cleaning the inverter
Use an air compressor, a soft dry cloth or soft-bristled brush to clean the inverter. Do not use water, corrosive
chemical substances or aggressive detergents to clean the inverter. Disconnect the AC and DC power to the
inverter before cleaning.
Cleaning the heatsink
Use an air compressor, a soft dry cloth or soft-bristled brush to clean the heatsink. Do not use water,
corrosive chemical substances or aggressive detergents to clean the heatsink. Disconnect the AC and DC
power to the inverter before cleaning.