Operations
Calibrate the Printer
44
P1016807-001 Rev. A ZM400 User Guide for UPS 2/26/10
Calibrate the Printer
Auto Calibration
By default, the printer automatically calibrates on power up or when the printhead is closed.
During auto calibration, the printer determines the label length and sensor settings.
The results of the auto calibration are stored in the printer’s memory and are retained even if
printer power is removed. These parameters remain in effect until the next calibration is
performed.
Manual Calibration
Perform a media sensor calibration to reset the sensitivity of the sensors so the media is
detected more accurately. If you change the type of media, your printer may operate better if
you perform this calibration.
For instructions, refer to Calibrate Media Sensor Sensitivity on page 63.
Note • If the control panel settings for MEDIA POWER UP or HEAD CLOSE are set to
LENGTH, NO MOTION, or FEED, the printer starts printing without auto calibrating. See
Select Media Power-Up Option on page 68 or Select Head Close Option on page 68.