Printer Configuration and Adjustment
Adjust Printer Settings
114
P1066582-003 ZT400 Series™ User Guide 8/25/15
Media and
Ribbon Sensor
Calibration
Calibrate the printer to adjust the sensitivity of the media and ribbon sensors.
For complete instructions on how to perform a calibration procedure, see Calibrate the
Ribbon and Media Sensors on page 142.
User menu item:
Main Menu >
TOOLS
Main Menu >
SENSORS
Related ZPL command(s):
~JC
SGD command used:
ezpl.manual_calibration
Control panel key(s):
Hold PAUSE + FEED + CANCEL for 2 seconds to
initiate calibration.
Printer web page:
The calibration procedure cannot be initiated through the
web pages. See the following web page for settings that
are set during sensor calibration:
View and Modify Printer Settings > Calibration
Important • Do not change these settings unless
you are told to do so by Zebra Technical Support
or by an authorized service technician.
Communication
Diagnostics Mode
Use this diagnostics tool to cause the printer to output the hexadecimal values for all
data received by the printer.
For more information, see Communication Diagnostics Test on page 194.
User menu item:
Main Menu >
TOOLS
Accepted values:
DISABLED
ENABLED
Related ZPL command(s):
~JD to enable, ~JE to disable
SGD command used:
device.diagnostic_print
Control panel key(s):
Hold
PAUSE + FEED for 2 seconds when the printer is
in the Ready state.
Table 6 • Tools (Continued)
MEDIA/RIBBON CAL
START
DIAGNOSTIC MODE
DISABLED